Timers
Delay on Operate
Types A 108, A 101, A 208, A 201
• Time ranges: 0.15 s to 600 s
• Automatic start
• Knob-adjustable time within range
• Oscillator-controlled time circuit
• Repeatability deviation: ≤ 1%
• Output: 10 A SPDT or 8 A DPDT relay
• Plug-in type module
• Scantimer housing
• LED-indication for relay on
• AC or DC power supply
Product Description
Ordering Key
A 108 024 600
Function
Output
Type
Mono-function, plug-in, de- relays can be used to pre-
lay on operate miniature time vent several motors from
relays up to 600 s (10 min) starting simultaneously due
Power supply
Time range
covering
ranges. These economical
3 individual time to power supply interruptions.
Type Selection
Plug
Output Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
8 pin
SPDT
DPDT
0.15- 6 s
1.5 - 60 s
15 -600 s
A 108 024 006
A 108 024 060
A 108 024 600
A 108 120 006
A 108 120 060
A 108 120 600
A 108 220 006
A 108 220 060
A 108 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 -600 s
A 101 024 006
A 101 024 060
A 101 024 600
A 101 120 006
A 101 120 060
A 101 120 600
A 101 220 006
A 101 220 060
A 101 220 600
Circular
8 pin
0.15- 6 s
1.5 - 60 s
15 -600 s
A 208 024 006
A 208 024 060
A 208 024 600
A 208 120 006
A 208 120 060
A 208 120 600
A 208 220 006
A 208 220 060
A 208 220 600
Circular
11 pin
0.15- 6 s
1.5 - 60 s
15 -600 s
A 201 024 006
A 201 024 060
A 201 024 600
A 201 120 006
A 201 120 060
A 201 120 600
A 201 220 006
A 201 220 060
A 201 220 600
Time Specifications
Time ranges
0.15- 6 s
1.5 - 60 s
15 - 600 s
Repeatability deviation
Time variation
Within rated power supply
and ambient temperature
≤ 1%
≤ 0.05%/V
≤ 0.2%/°C
Time range accuracy
0 to +10% on max.
min. actual time ≤ min.
set time
Reset
Time and/or relay
Power supply interruption
≥ 250 ms
Specifications are subject to change without notice (25.10.99)
1