Features
■ Standard 5-pin configuration
■ Fail-short design
■ Low capacitance
U
■
c
us Listed
®L
■ Meets Telcordia 1361 & RUS PE-80
requirements
Model C-303™ 5-Pin Gas Tube Protector Modules
Bourns® C-303™ 5-Pin Protector Modules provide overvoltage protection in the industry-standard 5-pin configuration for use in central
and remote office connector blocks as well as building entrance terminals.
The protector housing is made of self-extinguishing thermoplastic in black (standard service) or red (special service) colors. Modules
are available with either tin-alloy or gold-plated outside plant and central office pins. The ground pin is always tin-alloy plated. The pin
plating can be be matched with the receptacle plating of the connector block or building entrance terminal.
The protectors incorporate a fail-short design to ensure safe operation and protect people and equipment from prolonged electrical
surges.
Characteristics
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
DC Breakdown Voltage Range @ 2000 V/second....................................................................... 280-420 V
AC Breakdown @ 60 Hz .............................................................................................................. 280-420 V
Impulse Breakdown
100 V/µs................................................................................................................................. 625 V
1000 V/µs............................................................................................................................... 875 V
Insulation Resistance @ 100 Vdc ............................................................................................... > 1 GΩ
Insertion Loss @ 100 MHz........................................................................................................... Exceeds Category 5
Return Loss @ 100 MHz.............................................................................................................. Exceeds Category 5
Capacitance Tip to Ring @ 1 MHz .............................................................................................. < 1.25 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz ............................................................................ < 2.50 pF typical
1
Impulse Reset
52 V, 260 mA ......................................................................................................................... < 10 ms
135 V, 200 mA ....................................................................................................................... < 10 ms
150 V, 200 mA ....................................................................................................................... < 150 ms
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
10 A, 10/1000 µs ................................................................................................................... > 3000 operations
100 A, 10/1000 µs ................................................................................................................. > 300 operations
300 A, 10/1000 µs.................................................................................................................. > 100 operations
2
500 A, 10/1000 µs.................................................................................................................. > 400 operations
2,000 A, 10/250 µs................................................................................................................. > 25 operations
5,000 A, 20/100 µs................................................................................................................. > 2 operations
20,000 A, 8/20 µs................................................................................................................... > 1 operation
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
0.5 A rms continuous............................................................................................................. > 30 seconds
1 A rms, 1 second, 600 ft. cable............................................................................................ > 60 operations
1 A rms, 1 second, 1 mile cable ............................................................................................ > 60 operations
10 A rms, 1 second ............................................................................................................... > 5 operations
2
65 A rms, 11 cycles ............................................................................................................... > 1 operation
120 A rms, 0.1 second........................................................................................................... 1 operation
High Current Capability and Thermal Operation (Tip and Ring to Ground)................................. > 30 A rms, 15 min.
Storage and Operating Temperature .......................................................................................... -55 to +85 °C
Safety
60 A, 3 sec............................................................................................................................. Fail-short
120 A, 0.6 sec........................................................................................................................ Does not cause a fire hazard
350 A, 0.04 sec...................................................................................................................... Does not cause a fire hazard
30 A, 15 min........................................................................................................................... Fail-short, does not cause a fire hazard
Safety Standards Listing ............................................................................................................. UL Listed to United States and
Canadian safety standards
Notes:
1
Network applied.
Per RUS PE-80.
2
Specifications are subject to change without notice.