5秒后页面跳转
777499-02 PDF预览

777499-02

更新时间: 2022-12-24 18:47:07
品牌 Logo 应用领域
美国国家仪器公司 - NI 控制器
页数 文件大小 规格书
6页 519K
描述
Controller Area Network (CAN) Interfaces

777499-02 数据手册

 浏览型号777499-02的Datasheet PDF文件第2页浏览型号777499-02的Datasheet PDF文件第3页浏览型号777499-02的Datasheet PDF文件第4页浏览型号777499-02的Datasheet PDF文件第5页浏览型号777499-02的Datasheet PDF文件第6页 
Controller Area Network (CAN) Interfaces  
NI CAN Series 2 Interfaces for PCI, PXI, and PCMCIA  
• Hardware timing and synchronization  
with NI data acquisition, vision,  
and motion devices  
Operating Systems  
• Windows 2000/NT/XP/Me/98  
• LabVIEW Real-Time  
• 100% bus load; for up to 1 Mb/s  
• ISO 11898-compliant for standard  
(11-bit) and extended (29-bit)  
arbitration IDs  
Recommended Software  
• LabVIEW  
• LabWindows/CVI  
• Philips SJA1000 CAN controller  
• Available in high-speed,  
low-speed/fault-tolerant,  
and single-wire versions  
• Hardware timestamping  
• Intel 80386EX microprocessor  
for timed CAN frame transfer  
• Optical isolation up to 500 V  
• Import Vector database files  
with NI-CAN  
Other Compatible Software  
• C/C++  
• Visual Basic 6  
Application Software (included)  
• Bus monitor utility  
Driver Software (included)  
• NI-CAN  
Overview  
cables to take advantage of synchronization. For PCI boards, you can  
CAN interfaces meet the physical and electrical requirements for in- use a RTSI bus cable to share the signals. For PCMCIA-CAN, a  
vehicle automotive networks based on CAN. All CAN interfaces synchronization cable connects external timing and triggering signals  
include NI-CAN device driver software, with which you can import to the card to achieve synchronization between PCMCIA-CAN and  
CAN channels from Vector database files or create them in an PCMCIA, USB, or PCI data acquisition hardware.  
easy-to-use utility and program using a high-level API. With a  
National Instruments CAN interface and NI-CAN software, you can use LabVIEW Real-Time Compatibility  
a desktop, industrial, or notebook PC running Windows for a variety PCI and PXI CAN hardware works with LabVIEW Real-Time running  
of CAN applications, including automotive testing and diagnostics, on a PC or a PXI controller for deterministic control.You can download  
prototype design, factory automation, and machine control.  
your existing NI LabVIEW application to the target without specialized  
real-time OS programming knowledge. The real-time performance and  
synchronization mean you can use a standard PC or PXI chassis for  
CAN Bus and Analog Data Synchronization  
Recent advances in automotive test applications demand tighter applications such as rapid control prototyping, hardware-in-the-loop  
integration of CAN and other measurement devices. In many testing, and data logging.  
applications, you need to synchronize the physical parameters  
measured in time to correlate the data. You can program this Common Hardware  
synchronization in software, but OS latency sometimes introduces All National Instruments Series 2 CAN devices use the Intel 80386EX  
unacceptable delays for certain automotive test applications. microprocessor to handle communications directly on the interface  
National Instruments CAN, data acquisition, vision, and motion device. The 80386EX provides a dedicated environment for reliable,  
boards for PCI are equipped to share timing and triggering signals. high-performance CAN communications protocol stack execution.  
In a system, a CAN board can share timing and triggering signals Because acquisition and transmission timing occur on the board,  
with data acquisition, image acquisition, or motion control boards, CAN frames are not lost due to OS activity such as hard drive  
basing their actions on these signals. Determinism is maintained access, mouse movements, or virus scans. The physical layer of all  
between the trigger signal and the desired response because timing National Instruments CAN devices fully conforms to the ISO 11898  
and triggering signals are handled in hardware. The host PC software physical layer specification for CAN and is optically isolated to 500 V.  
interacts only to retrieve the data once it is acquired or to write You can interface to the CAN bus using a 9-pin male D-Sub (DB9)  
new data.  
connector. The Philips SJA1000 CAN controller implements typical  
Synchronization is available for PXI, PCI, and PCMCIA-CAN ISO 11898 CAN functionality and offers additional functionality to aid  
devices. For PXI modules, the timing signals are shared in the PXI in system development, such as listen-only mode, sleep/wakeup mode,  
trigger bus on the backplane; therefore, you do not need additional error counter access, and self-reception (echo) mode.  

与777499-02相关器件

型号 品牌 描述 获取价格 数据表
777508-01 NI SCXI Terminal Blocks

获取价格

777509-01 NI SCXI Terminal Blocks

获取价格

777519-90 NI Calibration

获取价格

7775-2 ETC PC SCREW TERMINALS

获取价格

7775-3 ETC PC SCREW TERMINALS

获取价格

77753-001 AMPHENOL Push-On Terminal

获取价格