描述
Limit Alarms (potentiometer adj.) A-UNIT

ARB-6134-J/BL 数据手册

 浏览型号ARB-6134-J/BL的Datasheet PDF文件第2页浏览型号ARB-6134-J/BL的Datasheet PDF文件第3页浏览型号ARB-6134-J/BL的Datasheet PDF文件第4页 
MODEL: ARB  
5: Pt 50 Ω (JIS'81)  
Limit Alarms (potentiometer adj.) A-UNIT  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)  
6: Ni 508.4 Ω  
RTD ALARM  
Functions & Features  
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)  
0: Specify  
• Providing SPDT relay outputs at preset input levels  
• Direct input from an RTD  
Note: Consult M-System for 2-wire RTD  
• Dual (Hi/Lo) trip  
SETPOINT ADJUSTMENTS  
• Linearization  
1: Single-turn screws  
• Burnout protection  
• "Active bridge" circuit containing two constant current  
sources allows large leadwire resistances up to 200 Ω  
• Energized or de-energized coil at a tripped condition  
selectable  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
• Hysteresis (deadband) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
Typical Applications  
• Annunciator  
• Various alarm applications  
50  
(1.97)  
[4] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
80  
(3.15)  
132  
(5.20)  
mm (inch)  
DC Power  
S: 12 V DC  
MODEL: ARB-[1]1[2][3]-[4][5]  
R: 24 V DC  
V: 48 V DC  
ORDERING INFORMATION  
• Code number: ARB-[1]1[2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. ARB-1111-B/BL/Q)  
P: 110 V DC  
[5] OPTIONS (multiple selections)  
Burnout  
• Temperature range (e.g. 0 – 200°C)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
blank: Upscale burnout  
/BL: Downscale burnout  
Other Options  
blank: none  
[1] INPUT RTD (2- or 3-wire)  
1: JPt 100 (JIS'89)  
/Q: Option other than the above (specify the specification)  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)  
3: Pt 100 (JIS'89)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
4: Pt 100 (JIS'97, IEC)  
/C02: Polyurethane coating  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
/C03: Rubber coating  
ARB SPECIFICATIONS  
ES-2113 Rev.8 Page 1/4  
http://www.m-system.co.jp/  

与ARB-6134-J/BL相关器件

型号 品牌 描述 获取价格 数据表
ARB-6134-J/Q MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ARB-6134-P MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ARB-6134-P/BL MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ARB-6134-P/Q MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ARB-6134-R MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格

ARB-6134-R/BL MSYSTEM Limit Alarms (potentiometer adj.) A-UNIT

获取价格