5秒后页面跳转
MPS-30_10 PDF预览

MPS-30_10

更新时间: 2022-11-24 00:30:17
品牌 Logo 应用领域
MEANWELL 医疗
页数 文件大小 规格书
2页 506K
描述
30W Single Output for Medical Type

MPS-30_10 数据手册

 浏览型号MPS-30_10的Datasheet PDF文件第2页 
30W Single Output for Medical Type  
MPS-30 series  
Features :  
Universal AC input / Full range  
Low leakage current 0.3mA  
Protections: Short circuit / Overload / Over voltage / Over temperature  
Fixed switching frequency at 100KHz  
Low cost  
High reliability  
3 years warranty  
EN60601-1  
IEC60601-1  
SPECIFICATION  
MODEL  
MPS-30-5  
MPS-30-12  
MPS-30-15  
MPS-30-24  
MPS-30-27  
MPS-30-48  
DC VOLTAGE  
5V  
12V  
15V  
24V  
27V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
5A  
2.5A  
2A  
1.2A  
1.1A  
0.6A  
0 ~ 5A  
25W  
0 ~ 2.5A  
30W  
0 ~ 2A  
30W  
0 ~ 1.2A  
28.8W  
240mVp-p  
3.0%  
0 ~ 1.1A  
29.7W  
240mVp-p  
3.0%  
0 ~ 0.6A  
28.8W  
240mVp-p  
2.0%  
RIPPLE & NOISE (max.) Note.2 80mVp-p  
VOLTAGE TOLERANCE Note.3 3.0%  
120mVp-p  
3.0%  
150mVp-p  
3.0%  
0.5%  
1.0%  
OUTPUT  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
HOLD UP TIME (Typ.)  
1.0%  
1.0%  
0.5%  
0.5%  
0.5%  
2.0%  
1.0%  
1.0%  
1.0%  
1.0%  
500ms, 30ms/230VAC  
500ms, 30ms/115VAC at full load  
70ms/230VAC  
12ms/115VAC at full load  
VOLTAGE RANGE  
88 ~ 264VAC auto switch  
47 ~ 63Hz  
120 ~ 370VDC  
FREQUENCY RANGE  
EFFICIENCY (Typ.)  
72%  
75%  
0.5A/230VAC  
76%  
77%  
78%  
78%  
INPUT  
0.8A/115VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
COLD START 30A/230VAC  
<0.3mA / 264VAC  
LEAKAGE CURRENT  
Above 105% rated output power  
Protection type : Hiccup mode, recovers automatically after fault condition is removed  
5.5 ~ 6.75V 13.2 ~ 16.2V 16.5 ~ 20.25V 26.4 ~ 32.4V  
OVERLOAD  
29.7 ~ 36.45V  
52.8 ~ 64.8V  
PROTECTION OVER VOLTAGE  
Protection type : Hiccup mode, recovers automatically after fault condition is removed  
Tj 135 typically (U1) detect on main control IC  
Protection type : Shut down o/p voltage, re-power on to recover  
-10 ~ +60 (Refer to output load derating curve)  
20 ~ 90% RH non-condensing  
OVER TEMPERATURE  
WORKING TEMP.  
WORKING HUMIDITY  
-20 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
0.03%/ (0 ~ 50  
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes  
VIBRATION  
UL2601-1, TUV EN60601-1, IEC60601-1 approved  
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT  
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH  
Compliance to EN55011 (CISPR11) Class B  
Compliance to EN61000-3-2,-3  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
SAFETY &  
ISOLATION RESISTANCE  
EMC  
EMI CONDUCTION & RADIATION  
(Note 4)  
HARMONIC CURRENT  
EMS IMMUNITY  
MTBF  
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, medical level, criteria A  
547Khrs min. MIL-HDBK-217F (25  
101.6*65.8*23.5mm (L*W*H)  
)
OTHERS  
NOTE  
DIMENSION  
PACKING  
0.16Kg; 90pcs/15.8Kg/1.02CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
File Name:MPS-30-SPEC 2010-11-29  

与MPS-30_10相关器件

型号 品牌 描述 获取价格 数据表
MPS-30_11 MEANWELL 30W Single Output for Medical Type

获取价格

MPS-30-12 MPD Low Cost, Open Frame 30W EN60601 (Medical) Approved AC/DC Power Supplies

获取价格

MPS-30-12 TOTAL-POWER 30W Single Output for Medical Type

获取价格

MPS-30-12 ASTRODYNE 30W Single Output for Medical Type

获取价格

MPS-30-12 MEANWELL 30W Single Output for Medical Type

获取价格

MPS30-12 ASTRODYNE 30W Single Output for Medical Type

获取价格