描述
Miniature Flow Sensor Has Electronic Temperature Compensation

AN884 数据手册

 浏览型号AN884的Datasheet PDF文件第2页浏览型号AN884的Datasheet PDF文件第3页浏览型号AN884的Datasheet PDF文件第4页浏览型号AN884的Datasheet PDF文件第5页浏览型号AN884的Datasheet PDF文件第6页 
SENSOR SIGNAL CONDITIONERS  
Application Note 884: Dec 13, 2001  
Miniature Flow Sensor Has Electronic Temperature Compensation  
Fluid analysis is essential in a wide range of current applications. Biology, medical  
analysis, genetic engineering, and many other fields rely on fast, precise, and  
reproducible chemical and biological analyses. Tools that automate the dosing and  
analysis of fluid samples are essential for affordable performance.  
Highly specialized electronic sensors have been designed to automate sample analysis, but the  
dosing of liquids – still a prominent issue – must be done physically. This operation is usually  
accomplished with specialized micro-syringes driven by stepper motors. It's easy to imagine the  
difficulty and expense associated with such setups.  
In a novel approach to this problem, DASA IMT and Seyonic SA (both of Neuchâtel,  
Switzerland) developed flow-through micro-fluidic dosing as part of a toolkit for experiments  
performed in space. As described in the following, a key element of that design was a micro-  
flow sensor device. Requirements were:  
·
·
·
·
·
·
Small size  
Chemical inertia  
Temperature stability  
Long-term stability  
Simple, easy, and fully automated recalibration  
Linear voltage-versus-pressure output  
One way to measure micro-fluidic flow is by measuring the pressure difference across a  
restriction integrated into a micro-flow channel. Pressure measurements are performed with  
dual piezo-resistive pressure sensors, one placed before the restriction and the other behind.  
To insure that the sensor is not affected or altered by chemically aggressive fluids, the fluid  
under pressure is applied to the back of the sensor diaphragm (whose monocrystal-line silicon  
is relatively insensitive to the chemicals) rather than the front. This unusual configuration  
protects sensitive microelectronic circuits on top of the sensor by shielding them from the  
liquid. To prevent error from mechanical-tension forces, the sensor is mounted on a thick  
ceramic substrate (Figure 1).  
www.maxim-ic.com/an884  
Page 1 of 6  

与AN884相关器件

型号 品牌 描述 获取价格 数据表
AN8845SB PANASONIC Audio Preamplifier, 1 Channel(s), 1 Func, Bipolar, PDSO36, 0.450 INCH, PLASTIC, SSOP-36

获取价格

AN8847 PANASONIC Head amplifier IC for CD-ROM drive for 32 times speed or more

获取价格

AN8847SB PANASONIC Head amplifier IC for CD-ROM drive for 32 times speed or more

获取价格

AN8848SB PANASONIC Audio Preamplifier, 1 Channel(s), 1 Func, Bipolar, PDSO36, 0.450 INCH, PLASTIC, SSOP-36

获取价格

AN8849SB PANASONIC Head amplifier IC for CD-ROM drive for 24 times speed or more

获取价格

AN8850 UTC MOTOR CONTROL CIRCUITS

获取价格