SIDACtor® Device
RoHS
This modified TO-220 package with Type 61 lead spacing offers a through-hole technology
SIDACtor protection solution.
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
V
V
S
V
T
I
I
I
I
H
DRM
DRM
S
T
Number *
Volts
180
200
220
240
270
300
Volts
220
240
260
290
330
360
Volts
µAmps
mAmps
Amps
mAmps
P2000AA61L
P2200AA61L
P2400AA61L
P2500AA61L
P3000AA61L
P3300AA61L
4
4
4
4
4
4
5
5
5
5
5
5
800
2.2
150
800
2.2
150
800
2.2
150
800
2.2
150
800
2.2
150
800
2.2
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
•
•
•
•
•
•
All measurements are made at an ambient temperature of 25 °C. I applies to -40 °C through +85 °C temperature range.
PP
I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
V
V
is measured at I
DRM.
is measured at 100 V/µs.
DRM
S
Special voltage (V and V
) and holding current (I ) requirements are available upon request.
DRM H
S
Surge Ratings in Amps
I
PP
0.2x310 * 2x10 *
8x20 *
10x160 * 10x560 * 5x320 * 10x360 * 10x1000 * 5x310 *
I
TSM
0.5x700 ** 2x10 ** 1.2x50 ** 10x160 ** 10x560 ** 9x720 ** 10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
di/dt
Amps/µs
500
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
A
20
150
150
90
50
75
75
45
75
20
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 43