S8981-02 技术参数

是否Rohs认证: 符合生命周期:Obsolete
Reach Compliance Code:unknown风险等级:5.84
阵列类型:FULL FRAME TRANSFER主体宽度:23.2 mm
主体高度:1.5 mm主体长度或直径:35.5 mm
水平像素:1500安装特点:SURFACE MOUNT
最大工作电流:2 mA最高工作温度:40 °C
最低工作温度:输出范围:5-11V
输出类型:ANALOG VOLTAGE封装形状/形式:RECTANGULAR
像素大小:20X20 µm传感器/换能器类型:IMAGE SENSOR,CCD
最大供电电压:5.25 V最小供电电压:4.75 V
表面贴装:YES端接类型:CABLE
垂直像素:1000Base Number Matches:1

S8981-02 数据手册

 浏览型号S8981-02的Datasheet PDF文件第2页浏览型号S8981-02的Datasheet PDF文件第3页浏览型号S8981-02的Datasheet PDF文件第4页浏览型号S8981-02的Datasheet PDF文件第5页浏览型号S8981-02的Datasheet PDF文件第6页浏览型号S8981-02的Datasheet PDF文件第7页 
I M A G E S E N S O R  
CCD area image sensor  
S8980, S8981-02  
Front-illuminated FFT-CCDs for X-ray imaging  
S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega (1500 × 1000) pixels each of  
which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making  
S8980 very reliable even over a long-term operation. The scintillator coated on the FOP is optimized to have high X-ray sensitivity and high  
resolution (20 Lp/mm).  
S8981-02 is an easy-to-use X-ray imaging module using S8980, with added functions such as a cable assembly and X-ray trigger circuit. S8981-  
02 is advanced type for S8981 and adapted both AC and DC X-ray sources.  
Features  
Applications  
Sensor has X-ray monitoring photodiode  
Compactness  
General X-ray imaging  
Non-destructive inspection  
5.1 mm thickness excluding I/O connector part  
High dynamic range: 12 bit  
Long-term stability  
Intra-oral X-ray imaging in dental diagnosis  
For use under 100,000 shots  
(60 kVp, 30 mR X-ray irradiation)  
Resolution: 20 Lp/mm  
1500 (H) × 1000 (V) pixel format  
Pixel size: 20 × 20 µm  
Coupled with FOS for X-ray imaging  
100 % fill factor  
Low dark signal  
Low readout noise  
MPP operation  
AC/DC X-ray source adapted  
Selection guide  
Type No.  
Number of  
total pixels  
Number of  
active pixels  
Active area  
[mm (H) × mm (V)]  
Cooling  
S8980  
S8981-02  
Non-cooled  
1508 × 1002  
1500 × 1000  
30 × 20  
General ratings  
Parameter  
S8980  
S8981-02  
CCD structure  
Fill factor  
Full frame transfer  
100 %  
Number of active pixels  
Pixel size  
Active area  
Vertical clock phase  
Horizontal clock phase  
Output circuit  
Dimensional outline  
Reliability  
1500 (H) × 1000 (V)  
20 (H) × 20 (V) µm  
30 (H) × 20 (V) mm  
2 phase  
2 phase  
Emitter follower without load resistance  
35.5 (H) × 23.2 (V) mm 38.7 (H) × 26.3 (V) mm  
100,000 shots at 60 kVp, 30 m Roentgen  
Scintillator on 1.5 mm FOP  
Window  
Other  
MPP mode (low dark current operation), module (S8981-02)  
1

与S8981-02相关器件

型号 品牌 描述 获取价格 数据表
S8981-02C HAMAMATSU CCD Sensor, 1500 Horiz pixels, 1000 Vert pixels, 5-11V, Rectangular, Surface Mount

获取价格

S8982 HAMAMATSU CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging

获取价格

S8984 HAMAMATSU CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging

获取价格

S8984-02_15 HAMAMATSU Front-illuminated FFT-CCD for X-ray imaging

获取价格

S8985-02 HAMAMATSU CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging

获取价格

S8985-02C HAMAMATSU CCD Sensor, 1700 Horiz pixels, 1200 Vert pixels, 5-11V, Rectangular

获取价格