Type
Part No.
Cold Cathode Lamp Inverter Drive module
INV 10 (O1- 100-020K)
CCFL output
Connector system
JST XHP-3
5VDC input
Connector system
JST XHP-2
TR1
R1
R2
C1
T1
L1
C2
TR2
L70 x W20 x H15
Drawing not to scale
All dimensions in mm
CHARACTERISTIC DATA
Single Output suitable for CCFL length:
Input Voltage
150 ~ 280 mm
5.0VDC ± 0.5V
Input Current
850 mA maximum
No Load Output Voltage
Lamp Output Voltage (VL)
Nominal Drive current (IL)
Operating frequency (f)
Operating temperature
Operating humidity
1100V rms minimum, 1350V rms nominal
550V rms nominal
5 mA ± 1mA
39 ± 5 kHz
0 ~ 50 ºC
5 ~ 70% RH
Operating life
20,000 hours @ 5.5VDC
NOTES:
1. The inverter module should be protected from moisture, condensation and freezing.
2. Suitable screening may be necessary for electromagnetic compatibility and protection.
3. The use of silicone rubber stranded wire is recommended for connecting the CFFL.
4. Danger of electric shock.