5秒后页面跳转
2026-25-C2F PDF预览

2026-25-C2F

更新时间: 2024-02-10 01:42:30
品牌 Logo 应用领域
伯恩斯 - BOURNS 电信电信集成电路
页数 文件大小 规格书
5页 329K
描述
SURGE ARRESTOR GDT 250V FSHORT

2026-25-C2F 技术参数

是否无铅: 含铅是否Rohs认证: 符合
生命周期:ActiveReach Compliance Code:unknown
风险等级:2.12JESD-30 代码:O-XXSS-P3
功能数量:1端子数量:3
最高工作温度:85 °C最低工作温度:-55 °C
封装主体材料:UNSPECIFIED封装形状:ROUND
封装形式:SPECIAL SHAPE认证状态:Not Qualified
表面贴装:NO电信集成电路类型:SURGE PROTECTION CIRCUIT
温度等级:OTHER端子形式:PIN/PEG
端子位置:UNSPECIFIEDBase Number Matches:1

2026-25-C2F 数据手册

 浏览型号2026-25-C2F的Datasheet PDF文件第2页浏览型号2026-25-C2F的Datasheet PDF文件第3页浏览型号2026-25-C2F的Datasheet PDF文件第4页浏览型号2026-25-C2F的Datasheet PDF文件第5页 
Features  
Applications  
Telecommunications  
Balanced TRIGARD®  
Approximately 8 mm diameter, 11 mm long Industrial electronics  
UL Recognized  
Custom configurations available  
High surge current rating  
Commercial electronics  
Consumer electronics  
Aircraft and military electronics  
Stable breakdown throughout life  
RoHS compliant* version available  
2026 Series - 3-Pole Gas Discharge Tube  
Characteristics  
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.  
Model No.  
2026-20  
200 V  
Characteristic  
2026-07  
2026-09  
2026-15  
2026-23  
2026-25  
2026-26  
DC Sparkover ±20 % @ 100 V/s  
75 V  
90 V  
150 V  
230 V  
250 V  
260 V  
Impulse Sparkover (1)  
100 V/μs  
275 V  
700 V  
275 V  
600 V  
350 V  
575 V  
425 V  
625 V  
450 V  
650 V  
475 V  
700 V  
475 V  
700 V  
1000 V/μs  
Model No.  
Characteristic  
2026-30  
2026-35  
2026-40  
2026-42  
2026-47  
2026-60  
DC Sparkover ±20 % @ 100 V/s  
300 V  
350 V  
400 V  
420 V  
470 V  
600 V  
Impulse Sparkover (1)  
100 V/μs  
550 V  
775 V  
625 V  
875 V  
675 V  
925 V  
725 V  
1000 V  
800 V  
1100 V  
925 V  
1250 V  
1000 V/μs  
(1)  
ribution.  
Impulse Transverse Delay.............................................1000 V/μs.................................................................< 75 ns  
10  
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09).............> 10  
Glow Voltage ................................................................10 mA.......................................................................~ 70 V  
Arc Voltage ...................................................................1A.............................................................................~ 10 V  
Glow-Arc Transition Current...........................................................................................................................< 0.5 A  
Capacitance .................................................................1 MHz.......................................................................< 2 pF  
DC Holdover Voltage (2) ...............................................>135 V, (52 V for Model 2026-07 & 2026-09,...........< 150 ms  
80 V for Model 2026-15)  
Ω
Impulse Discharge Current...........................................40000 A, 8/20 μs (3) .................................................. 1 operation minimum  
20000 A, 8/20 μs......................................................> 10 operations  
5000 A, 10/350 μs ................................................... 1 operation  
1000 A, 10/1000 μs .................................................> 400 operations  
Alternating Discharge Current......................................130 Arms, 11 cycles (3) ............................................. 1 operation minimum  
20 Arms, 1 s.............................................................> 10 operations  
Operation and Storage Temperature.............................................................................................................. -40 to +90 °C  
Climatic Category (IEC 60068-1).................................................................................................................... 40/ 90/ 21  
Moisture Sensitivity Level...............................................................................................................................  
...............................................................................................................................  
1
6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C  
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be  
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering  
process that does not exceed 210 °C.  
Notes:  
• Model number marking on tube: 26-xxx V.  
• The rated discharge current for TRIGARD® Gas Discharge Tubes is the total current equally divided between each line to ground.  
8
• Sparkover limits after life ±25 %, IR >10 Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).  
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
• At delivery AQL 0.65 Level II, DIN ISO 2859  
(2) Network applied.  
(3) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.  
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.  
Specifications are subject to change without notice. Users should verify actual device performance in their specific  
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the  
last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.  
WARNING Cancer and Reproductive Harm  
www.P65Warnings.ca.gov  

与2026-25-C2F相关器件

型号 品牌 描述 获取价格 数据表
2026-25C2FLF BOURNS 暂无描述

获取价格

2026-25-C2FLF BOURNS GAS DISCHARGE TUBE LIBRE DE PLOMO

获取价格

2026-25C2LF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE

获取价格

2026-25-C2LF BOURNS SURGE ARRESTOR GDT 250V

获取价格

2026-25-C2M136 BOURNS Surge Protection Circuit,

获取价格

2026-25-C3 BOURNS 3-Pole Gas Discharge Tubes Sparkover100V/s 250V 3 Pole

获取价格