5秒后页面跳转
2026-07-CF PDF预览

2026-07-CF

更新时间: 2024-01-02 12:58:26
品牌 Logo 应用领域
伯恩斯 - BOURNS /
页数 文件大小 规格书
3页 541K
描述
Telecom Protection Circuit,

2026-07-CF 技术参数

是否Rohs认证:符合生命周期:Active
Reach Compliance Code:compliantHTS代码:8542.39.00.01
Factory Lead Time:5 weeks风险等级:5.54
Is Samacsys:N湿度敏感等级:1
峰值回流温度(摄氏度):NOT SPECIFIED处于峰值回流温度下的最长时间:NOT SPECIFIED
Base Number Matches:1

2026-07-CF 数据手册

 浏览型号2026-07-CF的Datasheet PDF文件第2页浏览型号2026-07-CF的Datasheet PDF文件第3页 
Features  
Applications  
Telecommunications  
Balanced TRIGARD®  
Approximately 8 mm diameter, 11 mm long Industrial electronics  
UL recognized  
Commercial electronics  
Custom configurations available  
High surge current rating  
Stable breakdown throughout life  
RoHS compliant* version available  
Consumer electronics  
Automotive, aircraft, military electronics  
2026 Series - 3-Pole Gas Discharge Tube  
Characteristics  
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361  
Model No.  
Characteristic  
2026-07  
2026-09  
2026-15  
2026-20  
2026-23  
2026-25  
2026-26  
1
DC Sparkover 20 ꢀ ꢁ 100 ꢂVs  
75 ꢂ  
90 ꢂ  
150 ꢂ  
200 ꢂ  
230 ꢂ  
250 ꢂ  
260ꢂ  
Impulse Sparkover  
100 ꢂVµs  
275 ꢂ  
700 ꢂ  
275 ꢂ  
600 ꢂ  
350 ꢂ  
575 ꢂ  
425 ꢂ  
625 ꢂ  
450 ꢂ  
650 ꢂ  
475 ꢂ  
700 ꢂ  
475 ꢂ  
700 ꢂ  
1000 ꢂVµs  
Model No.  
Characteristic  
2026-30  
2026-35  
2026-40  
2026-42  
2026-47  
2026-60  
DC Sparkover 20 ꢀ ꢁ 100 ꢂVs  
300 ꢂ  
350 ꢂ  
400 ꢂ  
420 ꢂ  
470 ꢂ  
600 ꢂ  
Impulse Sparkover  
100 ꢂVµs  
500 ꢂ  
775 ꢂ  
625 ꢂ  
875 ꢂ  
675 ꢂ  
925 ꢂ  
725 ꢂ  
1000 ꢂ  
800 ꢂ  
1100 ꢂ  
925 ꢂ  
1250 ꢂ  
1000 ꢂVµs  
Impulse Transverse Delay.............................................1000 ꢂVµs.................................................................< 75 ns  
10  
Insulation Resistance ...................................................100 ꢂ (50 ꢂ for Model 2026–07 & 2026-09).............> 10  
Glow ꢂoltage ................................................................10 mA.......................................................................~ 70 ꢂ  
Arc ꢂoltage ...................................................................1A.............................................................................~ 10 ꢂ  
Glow-Arc Transition Current...........................................................................................................................< 0.5 A  
Capacitance .................................................................1 MHz.......................................................................< 2 pF  
Ω
2
DC Holdover ꢂoltage .................................................>135 , (52 ꢂ for Model 2026-07 & 2026-09,...........< 150 ms  
80 ꢂ for Model 2026-15)  
3
Impulse Discharge Current...........................................40000 A, 8V20 µs .................................................... 1 operation minimum  
20000 A, 8V20 µs......................................................> 10 operations  
5000 A, 10V350 µs ................................................... 1 operation  
1000 A, 10V1000 µs .................................................> 400 operations  
3
Alternating Discharge Current......................................130 Arms, 11 cycles ............................................... 1 operation minimum  
20 Arms, 1 s.............................................................> 10 operations  
Operation and Storage Temperature.............................................................................................................. -40 to +90 °C  
Climatic Category (IEC 60068-1).................................................................................................................... 40V 90V 21  
Optional Switch-Grade Fail-short device available.  
Notes:  
• UL recognized component, UL File E153537.  
• Model number marking on tube: 26-xxx .  
• The rated discharge current for TRIGARD® Gas Discharge Tubes is the total current equally divided between each line to ground.  
8
• Sparkover limits after life 25 ꢀ, IR >10 Ω (-25 ꢀ,+30 ꢀ for Model 2026-07, 2026-09 and 2026-60).  
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
• At delivery AQL 0.65 Level II, DIN ISO 2859  
1
Tube meets BT requirement Type 14 AV1 (210-310 ꢂ).  
Network applied.  
DC Sparkover may exceed 25 ꢀ after discharge, but will continue to protect without venting.  
2
3
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  

与2026-07-CF相关器件

型号 品牌 描述 获取价格 数据表
2026-07-CFLF BOURNS 3-Pole Gas Discharge Tube

获取价格

2026-07-CLF BOURNS Telecom Protection Circuit,

获取价格

2026-09 BOURNS 2026 Series - 3-Pole Gas Discharge Tube Telecommunications

获取价格

2026-09-A BOURNS 3-Pole Gas Discharge Tube

获取价格

2026-09-A1 BOURNS 3-Pole Gas Discharge Tube

获取价格

2026-09-A1F BOURNS 3-Pole Gas Discharge Tube

获取价格