ArmorStart Power Media
Control Power Trunk and Drop Cables
6-pin/5-used 16 AWG, STOOW PVC
Specifications
Trunk & Drop Cables
Mechanical
Coupling Nut Black epoxy coated zinc
Overmold Red Riteflex TPE
Insert Yellow Riteflex TPE
Contacts Brass / gold over palladium Nickel
Cable Grey PVC, 16 AWG, dual rated UL TC/Open Wiring and STOOW
Cable Diameter 0.44 in. +/- 0.12 in. (11.18 mm +/- 0.5 mm)
Electrical
UL Type TC 600V 90 °C Dry 75 °C Wet, Open Wiring or MTW 600V
Cable Rating
90 °C or STOOW 105 °C 600V - CSA STOOW 600V FT2
Assembly Rating 600V, 10 A
Environmental
Enclosure Type Rating IP67, NEMA 6P, 1200 psi washdown
Operating Temperature -20…90°C (-4…194°F)
Features
Dimensions—mm (inches)
Dimensions are approximate. Illustrations are not drawn to scale.
y 6-pin/5-used configuration to prevent
mis-wiring with network connectors
y One piece molded design
39.6 (1.56)
y 16 AWG exposed run (ER) rated cable
y Red overmolds to indicate presence of E-
stop wiring
25.4
(1.0) dia.
56.1 (2.21)
32.5
25.4
(1.28)
(1.0) dia.
7/8 in.
16 UN-2B
Female straight
Female 90 deg.
40.6 (1.6)
59.4 (2.34)
25.4
(1.0) dia.
32.5
(1.28)
7/8 in.
16 UN-2B
Extended Pin 3
Male straight
Male 90 deg.
Example of Cordset
Example of Patchcord