Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
Value
10
Unit
Tol.
Capacitance
Rated Voltage
Surge Voltage
Leakage Current
Dissipation Factor
Ripple Current
ESR
C
VR
0.25 V/ 120 Hz/ +20 °C
µF
20ꢀ
50
V (DC) max.
V (DC) max.
VS
1000 cycles @ 20 °C
2 min./ +20 °C
62.5
5
-
+
ILeak
µA
ꢀ
max.
max.
max.
max.
DF 0.25 V/ 120 Hz/ +20 °C
10
IRIPPLE
100 kHz @ 105 °C
750
120
mA
mΩ
0,3 -0,05
RESR
0.25 V/ 100 kHz/ +20 °C
1,4 ±0,2
1,4
3,0
O
5,0 ±0,5
Scale - 4,5:1
Schematic:
General Information:
Aluminum Hybrid Polymer Capacitors
Operating Temperature
-55 up to +105 °C
Storage Conditions
(in original packaging)
5 °C up to + 35 °C; 10 ꢀ up to 75 ꢀ RH
Endurance
10000 h
1
Moisture Sensitivity Level (MSL)
Test conditions of electrical properties: +20 °C, 35 ꢀ RH if not specified differently
FIT according to separate documentation
Surge Voltage: charging time 30 s, discharging time 330 s for a cycle
Scale - 4,5:1
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
FPu
001.001
2023-03-24
DIN ISO 2768-1m
DESCRIPTION
TECHNICAL REFERENCE
HSEC058100M050DVCPCK000
ORDER CODE
WCAP-HSG5 Aluminum Hybrid
Polymer Capacitors
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
875575759001
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
5.0 x 5.8
eiCap
Valid
1/9
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic
component which is used in electrical circuits that require high safety and reliability functions or performance.