Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
Value
470
2.5
Unit
Tol.
Capacitance
Rated Voltage
Surge Voltage
C
0.5 V/ 120 Hz/ +20 °C
µF
20ꢀ
VR
VS
V (DC) max.
V (DC) max.
1000 cycles @ 20 °C
2 min./ +20 °C
3.1
-
+
ILeak
Leakage Current
Dissipation Factor
Ripple Current
ESR
117.5
6
µA
ꢀ
max.
max.
max.
max.
DF 0.5 V/ 120 Hz/ +20 °C
IRIPPLE
100 kHz @ 45 °C
100 kHz @ 20°C
10200
3
mA
mΩ
1,3 0,3
1,3 0,3
RESR
4,0
8,8
2,4
Scale - 5:1
Schematic:
7,3 0,2
General Information:
Aluminum Polymer Capacitors
Polarity Mark
(Positive)
Storage Conditions
(in original packaging)
5 °C up to + 30 °C; 10 ꢀ up to 70 ꢀ RH
Operating Temperature
Endurance
-55 up to +105 °C
2000 h
3
-
+
Moisture Sensitivity Level (MSL)
Test conditions of Electrical Properties: +20 °C, 35 ꢀ RH if not specified differently
FIT according to separate documentation
Surge Voltage: Charging time 30s, discharging time 330s for a cycle
Scale - 5:1
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
PSL
003.000
2021-06-14
DIN ISO 2768-1m
DESCRIPTION
TECHNICAL REFERENCE
PSE2917471M2R5DH3T2HT19
ORDER CODE
WCAP-PHSE Aluminum Polymer
Capacitors
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
875046319001
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
7.3 x 4.3 x 1.9
eiCap
Valid
1/9
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.