Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
Value
220
25
Unit
Tol.
Capacitance
C
VR
0.25 V/ 120 Hz/ +20 °C
µF
20ꢀ
-
+
Rated Voltage
Surge Voltage
Leakage Current
Dissipation Factor
Ripple Current
Impedance
V (DC) max.
V (DC) max.
VS
1000 cycles @ 20 °C
2 min./ +20 °C
28.75
55
ILeak
µA
ꢀ
max.
max.
max.
max.
DF 0.25 V/ 120 Hz/ +20 °C
14
3,1 ±0,2
IRIPPLE
100 kHz @ 105 °C
530
220
mA
mΩ
0,35 -0,05
Z
0.25 V/ 100 kHz/ +20 °C
O
8,0 ±0,5
2,8
4,2
Schematic:
General Information:
Aluminum Electrolytic Capacitors
Operating Temperature
-55 up to +105 °C
Storage Conditions
(in original packaging)
5 °C up to + 35 °C; 10 ꢀ up to 75 ꢀ RH
Endurance
2000 h
1
Moisture Sensitivity Level (MSL)
Test conditions of electrical properties: +20 °C, 35 ꢀ RH if not specified differently
FIT according to separate documentation
Surge Voltage: charging time 30 s, discharging time 330 s for a cycle
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
FPu
002.000
2022-09-19
DIN ISO 2768-1m
DESCRIPTION
TECHNICAL REFERENCE
ASEE105221M025DVCTEB000
ORDER CODE
WCAP-ASLI Aluminum Electrolytic
Capacitors
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
865080453013
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
8.0 x 10.5
eiCap
Valid
1/9
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.