TOSGAGE Series
TOSGAGE
-7525
X-ray Thickness Gage
General
•
•
The operation-PC uses Windows® NT, and is a
user-friendly PC.
The X-ray thickness gage is used to measure the
thickness of a strip continuously without
contacting that strip. This gage uses the fact that
the amount of radiation that passes through the
strip varies with the thickness of that strip.
A newly-developed X-ray generator is used,
providing extremely accurate measurement
results with a quick response time. The
TOSGAGE-7525 focuses X-ray beams finely in
the strip width direction to improve thickness
resolution in the strip width direction, and
making it suited to measuring the shape of the
section of measured materials.
The TOSGAGE-7525 is a high quality thickness
gage for cold rolling achieving outstanding safety,
operability, accuracy and cost-performance
developed over many years. It has the following
features.
The TOSGAGE-7525 can also be used as a AGC
backup for when the fixed thickness gage
(TOSGAGE-7521/7522) has failed.
•
Noise immunity is improved by digitizing the
signals between the measuring head and the
equipment cabinet.
Configuration
Customer's
distribution panel
X-ray/shutter
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ*〈AVR〉
* Driving control box
* Equipment cabinet
warning lamp
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
⑤CVVS 3C 5.5S(AC200V)ꢀ ꢀꢀꢀ ③CVVS 2C 3.5S(AC200V)ꢀꢀꢀꢀꢀꢀ①CV 3C 3.5S(AC200V,1φ)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ⑳CVVS 8C 1.25S
35 NC-HIV 8S
⑥CVVS 3C 8S(AC100V)
④CVVS 2C 3.5S(AC100V)
⑪ Special cable (power)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
* Measuring head
⑦CVVS 20C 1.25S(Signal)
⑧CVVS 10P 1.25S(Signal)
⑫
Special cable (Signal)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
⑬
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
Special cable (Signal)
(Customer's
computer)
D-type
⑭
Special cable (Snet)
⑮
Special cable (motor power supply)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
⑨CVVS 10P 1.25S(Signal)ꢀꢀꢀꢀꢀꢀ2ꢀ2ꢀCVVS 4P 1.25S(Signal)
PG
B
M
⑯
Special cable (PG signal)
⑩5C-2V-CCY 23 CVVS 20C 1.25S(Signal)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
⑰ CVVS 2C 2S (reverse limit)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
29
CVVS 10P 1.25Sꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ26ꢀAUIꢀꢀꢀ27ꢀAUI
ꢀꢀꢀꢀꢀ(PG Signal)ꢀꢀꢀꢀꢀꢀꢀꢀꢀ24AUI
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ⑱ꢀꢀꢀCꢀVVꢀSꢀ2ꢀCꢀ2ꢀSꢀ(ꢀfoꢀrwꢀaꢀrdꢀꢀ
Transceiver
Bridge
Transceiver
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ⑲ꢀꢀꢀCꢀVVꢀSꢀ2ꢀCꢀ2ꢀSꢀ(ꢀstꢀanꢀdꢀbyꢀ)ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
34
Transceiver
* Limit switch
30
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀ
CVVS 2C 2S (line center)
NC-HIV 8S
21 NC-HIV 8SꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀAUI
25
Conditioꢀnꢀsꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
2
ꢀ
8
10BASE5
1. Apart from special cables ⑪ to ⑮, all cables are
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
(Operation-PC)
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
the responsibility of the customer.
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
D-type
C-type
Printer
2. Length of cable between equipment cabinet and
NC-HIV
33
32
automatic voltage regulator is 10m max.
3. Distance between automatic voltage regulator and
customer's distribution board is 10m max.
8S D-type
4. Length of cable between driving control box and
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ3ꢀ1 CV 3C 3.5S(AC100V,1φ)
customer's distribution board is 100m max.
②CV 3C 5.5S(AC200V,1φ)
5. LAN and terminators are the responsibility of the customer.
(Hub) bridging and LAN separation are the responsibility of the
customer.
6. The application of flame-resistant cable (judgment and liability) is the responsibility of the customer.
7. Components marked * are standard configuration components.
Figure 1
Configuration and Cable Connections
No. EJD-069
1