Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
1 MHz/ 5 mA
ΔT = 40 K
Value
0.25
9.35
8.5
Unit Tol.
Inductance
L
µH
A
15ꢀ
IR
Rated Current 1)
Saturation Current 1
Saturation Current 2
DC Resistance
max.
typ.
typ.
typ.
ISAT 1
ISAT 2
RDC
RDC
fres
|ΔL/L| < 10 ꢀ
|ΔL/L| < 30 ꢀ
@ 20 °C
A
15.65
26
A
mΩ
DC Resistance
@ 20 °C
31
mΩ max.
MHz min.
1,0 ±0,3
1,2 ±0,3
Self Resonant Frequency
150
1) refer to IEC 62024-2-2020
1,2
1,7
1,2
Certification:
RoHS Approval
3,2 ±0,2
Compliant [2011/65/EU&2015/863]
Conform or declared [(EC)1907/2006]
Conform [JEDEC JS709B]
REACh Approval
Halogen Free
Scale - 10:1
Halogen Free
Conform [IEC 61249-2-21]
AEC-Q200 Grade 1
Schematic:
Component Qualification
General Properties:
Ambient Temperature (referring
to IR)
-40 up to +85 °C
-40 up to +125 °C
< 40 °C ; < 75 ꢀ RH
1
Operating Temperature
Storage Conditions (in original
packaging)
Moisture Sensitivity Level (MSL)
Test conditions of Electrical Properties: +20 °C, 33 ꢀ RH if not specified differently
Test conditions of Rated Current: refer to IEC 62024-2-2020, Class C (PCB Copper Width: 40 mm;
PCB Copper Thickness: 105 µm)
Scale - 10:1
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
JKe
003.000
2023-09-07
DIN ISO 2768-1m
DESCRIPTION
WE-PMCI Power Molded Chip
Inductor
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
ORDER CODE
74479290125
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
1210
eiSos
Valid
1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic
component which is used in electrical circuits that require high safety and reliability functions or performance.