Features  
Reflective Beam  
• Models for ranges of:  
15 to 160 ft. (4.572 to 48.768 m)  
160 to 330 ft. (48.768 to 100 m)  
• Easy alignment.  
Smoke Detector  
• Calibrated obscuration test filters  
included.  
Description  
Gamewells reflective beam smoke  
detectors (72223-160 or 72223-330)  
are a single infrared transceiver  
• Selectable alarm thresholds: 25%, 35%,  
50%.  
• Microprocessor controlled.  
• Low current draw.  
and a reflective prism. The signal  
generated in the transmitter  
element and reflected by the prism  
back to the receiver element is  
analyzed for the presence of smoke.  
The internal microprocessor deter-  
mines an alarm condition when a  
• Selectable automatic reset.  
• Automatic gain control.  
• 12 VDC or 24 VDC operation.  
• Status LEDs.  
predetermined level is reached. The  
system is designed to be mounted so that the beam will project between 1  
foot (0.305 m) and 2 feet (0.61 m) below and parallel to the ceiling. Lateral  
detection may be up to 30 feet (9.144 m) to either side of the beam, provid-  
ing a maximum total area coverage of up to 19,800 square feet (60' x 330' or  
18.288 m x 100 m).  
• Separate trouble contacts.  
Engineer’s Specifications  
The projected beam type smoke detector shall be a four-wire 12/24 VDC  
device to be used with UL-Listed, separately supplied, four-wire control  
panels only. Unit shall be Listed to UL 268 and shall consist of an inte-  
grated transmitter and receiver. The detector shall operate between a range  
of 15 to 330 ft. (4.572 to 100 m). The temperature range of the beam shall  
be –22°F to 131°F (–30°C to 55°C). The beam detector shall feature auto-  
matic gain control which will compensate for gradual signal deterioration  
from dirt accumulation on lenses. The unit shall include a wall-mounting  
bracket. Testing shall be carried out using a calibrated test filter. The  
projected beam type smoke detector shall be Gamewell model 72223-160  
(160 ft./18.288 m) or 72223-330 (330 ft./100 m).  
Listings  
Listings and approvals below apply to the  
Reflective Beam Smoke Detectors. In  
some cases, certain modules may not be  
listed by certain approval agencies, or  
listing may be in process. Consult factory  
for latest listing status.  
Smoke Detector Spacing  
On smooth ceilings, up to 60 ft. (18.288 m) between projected beams and not  
more than one-half that spacing between a projected beam and a sidewall.  
Other spacing may be used depending on ceiling height, airflow characteris-  
tics, and response requirements. See NFPA 72 for further information.  
• UL Listed:  
Reflective Beam CS-2154 06/23/04  
Page1 of 2  

与72224相关器件

型号 品牌 描述 获取价格 数据表
72224-45-56 MOLEX Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)

获取价格

72224-49 MOLEX Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)

获取价格

72224-50 MOLEX Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s),

获取价格

72224-58 MOLEX Barrier Strip Terminal Block

获取价格

72224-59 MOLEX Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)

获取价格

72224-P MOLEX Barrier Strip Terminal Block

获取价格