Multiple Case Sizes - High Voltage High Current
FEATURES
–
Bulk Filtering Switching Power Supplies
APPLICATIONS
–
-40°C to +105°C (<100WVDC)
-25°C to +105°C (>160WVDC)
Operating Temperature Range
Capacitance Tolerance
WVDC
+20% at 120 Hz, 20°C
10
13
10
.6
16
20
16
.45
25
32
25
.3
35
44
35
.25
50
63
50
.2
63
79
63
.15
80
100 160 200 250 350
400 450
450 500
400 450
Surge Voltage
SVDC
100 120 200 250 300 400
Dissipation
Factor
WVDC
80
100 160 200 250 350
.15 .15 .15 .15 .15
.15
.2
.2
tan δ
(120 Hz)
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
Leakage Current @20°C,
Rated WVDC applied
Time
5 Minutes
3√CV
WVDC
10
6
16
6
25
6
35
6
50
4
63
3
80
3
100 160 200 250 350 400 450
Impedance Ratio
-25°C/+20°C
3
8
-
8
-
8
-
8
-
8
-
8
-
(120 Hz)
-40°C/+20°C
15
15
15
15
15
15
15
5000 hours at 105°C with rated WVDC and ripple current applied
Capacitance change
Dissipation factor
Leakage current
<20% of initial measured value
Load Life
Shelf Life
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 105°C with no voltage applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
Leakage Current
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Temperature (°C)
60
0.9
0.8
0.8
120
1.0
1.0
1.0
400
1.0
1.0
1.0
1k
10k
1.25
1.47
1.47
50k
1.25
1.47
1.47
45
2.4
2.4
2.4
65
2.1
2.1
2.1
75
1.9
1.9
1.9
85
1.7
1.7
1.7
105
WVDC
<100
160<V<250
>350
Ripple Current
Multipliers
1.15
1.25
1.3
1
1
1
Sep-21