Multiple Case Sizes - High Voltage High Current
FEATURES
–
Filtering Switching Power Supplies
APPLICATIONS
–
-40°C to +105°C (<250WVDC)
-25°C to +105°C (>250WVDC)
+20% at 120 Hz, 20°C
Operating Temperature Range
Capacitance Tolerance
WVDC
Surge Voltage
10
16
25
35
50
63
80
100 160 200 250 350
400 450
SVDC
13
10
.55
20
16
.5
32
25
.45
44
35
.4
63
50
.35
79
63
.3
100 120 200 250 300 400
80
.25
450 500
400 450
Dissipation
Factor tan
δ
WVDC
100 160 200 250 350
.2 .15 .15 .15 .15
.15
.15
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
(120 Hz)
Leakage Current @20°C,
Rated WVDC applied
Time
5 Minutes
3√CV
WVDC
10
4
16
4
25
4
35
4
50
4
63
4
80
4
100 160 200 250 350 400 450
Impedance Ratio
-25°C/+20°C
4
3
3
3
8
-
8
-
8
-
(120 Hz)
-40°C/+20°C
15
15
15
15
15
15
15
15
15
15
15
2000 hours with rated voltage and rated ripple current applied at 105°C
Capacitance Change
Dissipation Factor
Leakage Current
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
Load Life
Shelf Life
1000 hours at 105°C with no voltage applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
Leakage Current
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Temperature (°C)
60
0.8
0.8
120
1.0
1.0
400
1.1
1.1
1k
10k
1.25
1.47
50k
1.25
1.47
40
2.5
2.5
60
2.2
2.2
70
2
85
1.8
1.8
105
1
Ripple Current
Multipliers
WVDC
<100
>160
1.15
1.15
2
1
Sep-21