Technical Data
Magnetic sensors
Series MA-11
MEK-E29NS/H10-K2
6362611008
Type designation
Item number
Wiring diagram
M
active surface
Characteristic features in accordance with EN 60947-5-2
Electrical data
Assured operating distance
Switching function
Sa
17 mm
NPN, open collector, N.O.
Operational voltage range
Switching current
UB
4,5-24 VDC
25 mA
Supply current
< 5 mA
Voltage drop
Switching element
Ud
f
< 1 V
Hall (south activated), typ. 10 mT
current limit
20 kHz
optional
yes
T-62 N/S
Short-circuit protection
Frequency of operating cycles
Assembly position
False polarity protection
Corresponding magnet
Electromagnetic compatibility (EMC)
Electromagnetic field test
Electrostatic discharge test
Electrical fast transient immunity test (Burst)
Radiated disturbance field strength
IEC 61000-4-3
IEC 61000-4-2
IEC 61000-4-4
EN 55011
Mechanical Data
Enclosure
PA 66
Ambient air temperature
Type of protection
Termination type
For attachment
-25 °C … +70 °C (cabel fixed mounted)
IP67 acc. to IEC 529, EN 60529
cabel 3 x 0,14 mm² x 2 m; PVC-Outer jacket, black
none
EU Conformity
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual from the here described condition are excluded. Subject to modifications and amendments.
Date of issue: 29.06.2007 / Page 1 of 1
Document: 6362611008_en.doc / Last update: 1 / 0189-07
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Vorlage : 08501740306 Orig. 1