POWER ENTRY MODULES / GERÄTESTECKER-KOMBIELEMENTE
6200/02/05, 6220
Power entry modules
Types 6200/02/05, 6220
– Panel mount: – screw-on version, front or rear-side
– snap-in version, front-side
– Appliance inlet, fuseholder for fuses 5 x 20 mm,
1- and 2-pole
– Version with line filter/shield see page 95
Types
6200, 6205
6200, 6205
Plug removal necessary
for fuse replacement
1-pole
50
75
100
Types
6220
6220
Type / Typ 6202: for protection class II
2-pole
Characteristics
•
•
•
•
•
Available with or without internal connections
Plug removal necessary for fuse-link replacement
The fuseholder is accessible from the equipment front
Types 6200/6205 with spare fuse compartment
Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated current
250 VAC
10 A
Dielectric strength
(50 Hz, 1 Min.)
Types 6200/05 > 2 kV between L-N and
Types 6220
Type 6202
between L/N-PE
> 2 kV between L-N and
> 4 kV between L/N-PE
Allowable ambient air
a
temperatures T
–25 °C to +70 °C
Degree of protection (front side) IP 40 acc. to IEC 60529
Protection class
Terminals
suitable for equipment with protection
class I and II acc. to IEC 61140
Solder 3,5 x 0,8 mm or
quick-connect 4,8 x 0,8 mm or
quick-connect 6,3 x 0,8 mm, tin-plated
screw-on: max. 6 mm
snap-in: 1/1,5/2/2,5/3 mm
Thermoplastic, black, UL94 V-0
Panel thickness s
Materials: Housing
Appliance-inlet
acc. to IEC/EN 60320-1/C14,
protection class I, C18 protection class II
pin-temperature 70 °C (cold condition)
1- or 2-pole, shocksafe category PC2
acc. to IEC/EN 60127-6,
Fuseholder
for fuse-links 5 x 20 mm
Rated power acceptance at
a
ambient air temp. T 23 °C
2 W (1-pole) 1,6 W (2-pole) per pole
see derating curves. Take note of
the information on page 197
Admissible power acceptance
a
at higher T
Type 6220:
Patents in U.S. (No. 4, 959, 025) and in further countries
33