5秒后页面跳转
60F-161-R PDF预览

60F-161-R

更新时间: 2024-09-17 02:50:35
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
4页 134K
描述
Field Network Modules 60-UNIT Series

60F-161-R 数据手册

 浏览型号60F-161-R的Datasheet PDF文件第2页浏览型号60F-161-R的Datasheet PDF文件第3页浏览型号60F-161-R的Datasheet PDF文件第4页 
MODEL: 60F  
Field Network Modules 60-UNIT Series  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
ANALOG I/O MODULE  
(Fuji Electric T-Link use)  
/C02: Polyurethane coating  
/C03: Rubber coating  
Functions & Features  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
• Interfacing analog I/O signals from/to 10-RACK or 18-RACK  
modules with T-Link  
• Saving power and I/O wiring inside an instrumentation  
panel  
RELATED PRODUCTS  
•Special cable (model: MCN34)  
72  
(2.83)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection  
80 (3.15)  
T-Link: Euro type connector terminal (applicable wire size:  
0.2 to 2.5 mm , stripped length 7 mm)  
2
I/O: 34-pin connector (OMRON XG4A-3434)  
Power input: M3.5 screw terminal  
153 (6.02)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
mm (inch)  
Housing material: Flame-resistant resin (black)  
Isolation: I/O to T-Link to power to FG1  
Power indicator: Green LED turns on with power supplied.  
MODEL: 60F-16[1]-[2][3]  
T-Link SPECIFICATIONS  
Configuration: Multi-drop  
ORDERING INFORMATION  
• Code number: 60F-16[1]-[2][3]  
Specify a code from below for each [1] through [3].  
(e.g. 60F-161-K/Q)  
Communication: Half-duplex  
Baud rate: 500 kbps  
Transmission media/distance:  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
KPEV-SB 0.75 mm  
2
× 1 pair, 700 m  
× 1 pair, 1000 m  
T-KPEV-SB, 1.25 mm  
2
Station No.: Rotary switch; 00 - 99  
NO. OF CHANNELS  
16: 16 points  
(Factory default setting: 00)  
L RUN indicator: Red LED ON at normal communication  
L ERR. indicator: Red LED ON/blinking at communication  
abnormality  
[1] I/O TYPE  
1: Input  
L I/O indicator: Red LED blinking at normal I/O  
L COM indicator: RED LED blinking at T-Link normal  
communication  
2: Output  
NUMBER OF CONNECTABLE UNITS WITH T-Link  
Up to a maximum of 32 T-Link devices can be connected in  
a single T-Link system. There is a limit of 100 words in  
processor memory. Make sure that the configured word  
area to be occupied does not exceed the 100-word range.  
(According to the Fuji Electric MICREX-F Users Manual)  
It is necessary to consider these criteria when connecting to  
this device.  
[2] POWER INPUT  
AC Power  
K: 85 – 132 V AC  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
The below describes the number of words occupied per  
device by number of modules.  
[3] OPTIONS  
For input 16 / output 16 modules: 16  
blank: none  
/Q: With options (specify the specification)  
60F SPECIFICATIONS  
ES-6610 Rev.3 Page 1/4  
http://www.m-system.co.jp/  

与60F-161-R相关器件

型号 品牌 获取价格 描述 数据表
60F-161-R/Q MSYSTEM

获取价格

Field Network Modules 60-UNIT Series
60F-162-K MSYSTEM

获取价格

Field Network Modules 60-UNIT Series
60F-162-K/Q MSYSTEM

获取价格

Field Network Modules 60-UNIT Series
60F-162-R MSYSTEM

获取价格

Field Network Modules 60-UNIT Series
60F-162-R/Q MSYSTEM

获取价格

Field Network Modules 60-UNIT Series
60F30AB3 JSMC

获取价格

TO-3PB
60F30DAB3 JSMC

获取价格

TO-3PB
60F30DWS3 JSMC

获取价格

TO-247S
60F30SAB3 JSMC

获取价格

FAST RECOVER DIODE
60F30SW3 JSMC

获取价格

FAST RECOVER DIODE