60DDW_3 Series
60W - Single/Dual Output - Wide Input - Isolated & Regulated
DIP DC-DC Converter
DC-DC Converter
60 Watt
High efficiency up to 88%
2:1 wide input voltage range
Isolation voltage 3000VDC
Six-sided metal shield
Short circuit protection (SCP)
(automatic recovery)
Operating temperature:
-40°C to +85°C
Over temperature protection
Industry standard pinout
Under voltage lockout
The 60DDW series offers 60W of output, wide input voltage of
9-18VDC, 18-36VDC and 36-72VDC and features 3000VDC isolation,
six-sided metal shield over current and short circuit protection.
All models are particularly suited to tele-communications, industrial,
test equipments power etc.
Common specifications
Cooling:
Output specifications
Free air convection
Item
Test condition
Min Typ
Max
2
Units
%
Short circuit protection:
Operation temperature range:
Storage temperature range:
Case temperature:
Continuous, auto-recovery
-40°C~+85°C
Voltage tolerance Single/dual
Over load
protection
Input voltage range
120
150
180
%
-55°C~+100°C
Line regulation
Single & Dual
(H/L to L/L)
0.5
0.5
%
%
90°C MAX
Lead temperature range:
Switching frequency (PWM mode):
Humidity:
265°C MAX, 1.5mm from case for 10 sec
50kHz TYP
Load regulation
Single & Dual
(25% to 100% load)
Minimum load
30% of full load
non-condensing, 95% MAX
Six-Side Shielded Case
Epoxy (UL94V-0 rated)
EN55022, Class A
EN55022, Class A
>299,424 hours
Ripple and noise*
20MHz Bandwidth
150
mVp-
p
Case material:
Potting material:
Transient respon-
se setting time
50% load step change
400
1500
µs
Radiated Emissions:
Conducted Emissions:
MTBF (MIL-HDBK-217F @25°C)*:
Weight:
Capacitive load
µF
External Trim Adj.
Range
10% of Output
Voltage
227.5g
* Test ripple and noise by “parallel cable” method. Typical value at nominal
input voltage and no load.
Input specifications
Example:
60DDW_2415S3
Item
Test condition
Pi network
Min
Typ
Max
Units
60 = 60Watt; D = DIP; D = series; W = wide input (2:1) 24 = 18-36Vin;
15Vout; S = single output; 3 = 3000VDC isolation
Filter
Protection
Fuse recommended
Isolation specifications
Item
Test condition
Min
Typ Max
3000
Units
VDC
Isolation voltage
Input/Output, tested
for 1 minute
Note:
1. Input voltage can’t exceed this value, or will cause the permanent damage.
2. The load shouldn‘t be less than 5%, otherwise ripple will increase dramati-
cally.
Isolation resistance
500VDC
1000
MΩ
pF
Isolation capacitance Input/Output
2500
3. Max. Capacitive Load is tested on Vin-nominal and full load.
4. All specifications measured at Ta = 25°C, humidity <75%, nominal input
voltage and rated output load unless otherwise specified.
5. In this datasheet, all the test methods of indications are based on corporate
standards.
6. Only typical models listed, other models may be different, please contact our
technical person for more details.
7. Specifications subject to change without notice.
Page 1 of 3
60DDW_3 – Rev. 2020-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG