Metallized Polypropylene - High Capacitance – Low ESR
FEATURES
Switching Power Supplies – UPS – DC Link – Motor Speed Controls –
Solar Heaters – Power Converters
APPLICATIONS
-40°C to +100°C
Above +85°C applied voltage must be de-rated by 1.5%/°C
Operating Temperature Range
Capacitance Tolerance
+10% at 1 kHz, 25°C
+5% optional
VDC
Non-repetitive
SVDC
250
330
400
600
700
850
Surge Voltage
AC voltage
400
400
600
800
1000
1200
VDC
VAC
250
330
400
600
700
850
160
220
250
330
400
500
5uF<C<2
5uF
Dissipation Factor (MAX)
Tan δ
C< 5uF
.06%
C>75uF
at 1 kHz and 25°C
.1%
.15%
Insulation Resistance
After 1 minute of 100VDC applied
between the terminals at 25°C
30000 MΩxuF
“Not to exceed 3GΩ”
Self Inductance
Long term stability
<1 nano-Henry per mm of lead spacing
Capacitance variation <1% MAX after 2 years
Terminal to Terminal
Terminal to case
160% of VDC VDC applied for 10
Seconds and 25°C or
200% of VDC applied for 2 Seconds
and 25°C
Dielectric Strength
3KVAC at 50/60 Hz applied between the terminals and
case for 60 Seconds and 25°C
>100000 with VDC
>30000 with VAC
300/billion component hours
Performance requirements
Life Expectancy
Failure quota
Test Condition
Temperature= +40°C +2°C
Max Capacitance change
< 2% of initially measured valued
< 200% of initially specified valued
> 50% of minimum specified value
Damp Heat Test
Relative Humidity=93 +2%
DF Change
Test length= 56 days
Max Capacitance change
DF Change
Insulation resistance
<1% of initially measured value
< .1% at 1kHz
>50% of minimum specified value
Resistance to soldering Heat
Solder bath temperature: +260°C +/- 5°C
Exposure time: 10 seconds +/- 1 second
Insulation resistance
Construction
Electrodes
Metallized Polypropylene film
Vacuum deposited Metal layers
Coating
Lead terminations
Flame retardant tape wrap (UL510) with epoxy end fill (UL94V-0)
Lead free tinned copper leads
Special Order Options
Oct-21