High Current - High Voltage – Good Pulse Current Rating
FEATURES
Resonant Circuits – Switching Power Supplies –
Motor Speed Controls – Induction Heaters
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-40°C to +100°C
+10% at 1 kHz, 25°C
+5% optional
WVDC
SVDC
WVDC
VAC
250
400
250
160
330
500
330
220
400
600
400
275
600
800
600
350
700
1000
700
400
850
1200
850
500
Non-Recurrent SVDC
AC voltage (50/60 Hz)
For T>+85°C , The voltage (DC/AC)must be decreased by (1.5/2.5)% per °C
Frequency
C<5uF
5<C<25uF
C>25uF
Dissipation Factor (MAX)
25°C
(kHz)
1
0.05%
0.08%
0.1%
Insulation Resistance
30000 MΩxuF
(not to exceed 30GΩ)
Insulation Resistance
@25°C (<70% RH)for 1 minute at
100VDC applied
Self Inductance
Capacitance Drift Factor
<1 nano-Henry per mm of lead spacing
<0.5% after 2 years at 40°C
100000 Hours @WVDC
Life Expectancy
Failure quota
30000 Hours @ VAC
<3% of initially measured value
Capacitance Change
300/ Billion component hours
56 days at40°C with 90 to 95%RH, +40°C and no voltage applied
Capacitance Change
Dissipation Factor
<2% of initially measured value
<0.001 at 1kHz and 25°C
Damp Heat test
Insulation Resistance
>50% of maximum specified value
Self Inductance
Capacitance Drift Factor
Capacitance Temperature
Coefficient
<1 nano-Henry per mm of lead spacing
<0.5% after 2 years at 40°C
-200 ppm/°C, +100ppm/°C
Terminal to Terminal
Terminal to case
3kVAC @ 50/60 Hz applied between
terminals and case for 60 seconds at
25°C
160% of rated VDCApplied for 10
seconds or 150% VAC applied for 2
Seconds and 25°C
Dielectric Strength
Dielectric
Polypropylene
Construction
Metallized film
Coating
Leads
Flame Retardant plastic box with epoxy resin (UL94V-0)
Lead free tinned copper leads