www.hamlin.com
59090 Heavy DutyVane Sensor Features and Benefits
Features
Benefits
Applications
• Sensor and magnet contained in
single housing
• Quick and reliable single screw
mounting with location feature
• No standby power requirement
• Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
• Position and limit sensing
• Security system switch
• Linear actuators
• Sensor operates when ferrous vane
passes through slot
• Normally closed standard, normally
closed high voltage or change over
options
• Industrial process control
• Shaft rotation sensing
•
Choice of cable length and connector
contamination
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
ContactType
Form A
Normally
Closed
Normally Closed
HighVoltage
Change
Over
Switch Type
4
10
5
10
3
Power
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
Ω - max.
Ω - min.
pF - typ.
°C
5
175
Voltage
Switching
Breakdown
Switching
Carry
200
300
250
450
200
Current
0.5
0.5
0.25
1.2
1.5
1.5
Resistance
Contact, Initial
Insulation
Contact
0.2
1010
0.2
1010
0.2
109
Capacitance
Temperature
0.3
0.2
0.3
Operating
Storage
-40 to +85
-65 to +85
1.0
-20 to +85
-65 to +85
1.0
-40 to +85
-65 to +85
3.0
°C
Time
Operate
ms - max.
ms - max.
G - max.
Release
1.0
1.0
3.0
Shock
11ms 1⁄2 sine
50-2000 Hz
100
100
50
Vibration
G
- max.
30
30
30
CUSTOMER OPTIONS - Cable Length andTermination Specification
TABLE 2
TABLE 3
ACTIVATION
Termination Options:-
CableType:-
BS 6500 3A 16/0.2 PVC
DOUBLE INSULATED
SELECT
OPTION
DESCRIPTION
(2 WIRE VERSIONS ILLUSTRATED)
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
(in) mm
A or F Tinned or untinned leads
01
02
03
04
05
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
B
C
Crimped terminals
6.35mm fastons
ORDERING INFORMATION
5909306
X
T
XX
X
Series 59090
Table 1
SwitchType
Sensitivity
Table 2
Table 3
Cable Length
Termination
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
Hamlin USA
Hamlin UK
Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com
Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 6047 3000 • Fax: +33 (0) 1 6015 9136 • Email: sales.fr@hamlin.com
ISSUE No: 5 DATE: 16/10/08
31