www.hamlin.com
File E61760(N)
59085Vane Sensor Features and Benefits
Features
Benefits
Applications
59085 Sensor
• Sensor and magnet contained in
single housing
• Quick and reliable single screw
mounting with location feature
• No standby power requirement
• Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
• Position and limit sensing
• Security system switch
• Linear actuators
• Sensor operates when ferrous vane
passes through slot
• Normally open, normally closed or
change over options
• Choice of cable length and
connector
• Industrial process control
• Shaft rotation sensing
contamination
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
ContactType
Form A
Normally
Open
Change
Over
Normally
Closed
Normally
Closed H.V.
Switch Type
1
3
4
5
Power
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
Ω - max.
Ω - min.
pF - typ.
°C
5
5
10
10
Voltage
Switching
Breakdown
Switching
Carry
175
175
200
300
200
200
250
450
Current
0.25
0.25
0.5
0.5
1.5
1.5
1.2
1.5
Resistance
Contact, Initial
Insulation
Contact
0.2
109
0.2
109
0.2
1010
0.2
1010
Capacitance
Temperature
0.3
0.3
0.3
-40 to +105
-65 to +105
1.0
0.2
-20 to +105
-65 to +105
1.0
Operating
Storage
-40 to +105
-40 to +105
°C
-65 to +105
-65 to +105
Time
Operate
ms - max.
ms - max.
G - max.
3.0
3.0
50
3.0
3.0
50
Release
1.0
1.0
Shock
11ms 1⁄2 sine
50-2000 Hz
100
100
Vibration
G
- max.
30
30
30
30
CUSTOMER OPTIONS - Cable Length andTermination Specification
TABLE 2
TABLE 3
ACTIVATION
Termination Options:-
CableType:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
SELECT
OPTION
DESCRIPTION
(2 WIRE VERSIONS ILLUSTRATED)
.285 (7.3)
MAX
Standard Lengths
A or F Tinned or untinned leads
SELECT
OPTION
CABLE
LENGTH
(in) mm
B
C
D
E
Crimped terminals
6.35mm fastons
Mu METAL
1.0 SQ x .062
01
02
03
04
05
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
VANE
MOVEMENT
AMP MTE 2.54mm pitch
JST XHP 2.5mm pitch
MUST OPERATE
MUST RELEASE
ORDERING INFORMATION
5908356
X
T
XX
X
Series 59085
Table 1
SwitchType
Sensitivity
Table 2
Table 3
Cable Length
Termination
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
Hamlin USA
Hamlin UK
Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com
Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: sales.fr@hamlin.com
ISSUE No: 4 DATE: 1/5/3
30