Multiple Case Sizes - High Voltage – High Current
Filtering – Switching Power Supplies
FEATURES
APPLICATIONS
Operating Temperature
Range
-40°C to +105°C
-25°C to +105°C
Capacitance Tolerance
+20% at 120 Hz, 20°C
WVDC
SVDC
WVDC
Tan δ
10 16
13 20
10 16
.55 .5
25
32
25
.45
35
44
35
.4
50
63
50
.35
63
79
63
.3
80
100
80
100
120
100
.2
160
200
160
.15
200 250 350 400 450
250 300 400 450 500
200 250 350 400 450
Surge
Voltage
Dissipation
Factor
.25
.15
.15
.25
.25
.25
For capacitance values above 33000μF
(capacitance-33000 μF)*0.1
The add following to the Dissipation factors values above
10000 μF
5 Minutes
3√CV or 5000uA,Whichever is less
Leakage current
WVDC
-25°C to
+20°C
-40°C to
+20°C
Low
Temperature
Stability
Impedance Ratio
(120 Hz)
10 16
25
35
50
63
80
100 160 200 250 350 400 450
6
6
6
6
4
3
3
3
8
-
8
-
8
-
8
-
8
-
8
-
15 15
15
15
15
15
15
15
3000 hours at 105°C with rated WVDC and ripple current applied
Capacitance Change
Dissipation Factor
Leakage Current
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Load Life
Capacitance Change
Dissipation Factor
Leakage Current
Shelf Life
WVDC
60
0.9
0.8
0.8
120
1
1
1k
10k+
1.25
1.47
1.47
Ripple Current
Multipliers
10 to 100
160 to 250
350 to 450
1.15
1.25
1.3
1
Sep-21