Power entry modules with line filter
Felcom 54
www.schurter.com/pg06
Inlet filter, modular assembling
Standard- or Medical-Filter
5411.XX5X.XXX
Appliance inlet
Fuseholder
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
Line filter
C14
70° C
Description
-ꢀPanelꢀMount:
Characteristics
-ꢀModularꢀcomponentꢀselection
-ꢀIndividualꢀcomponentsꢀsolderedꢀonꢀaꢀprintedꢀcircuitꢀboard
-ꢀPlugꢀremovalꢀnecessaryꢀforꢀfuse-linkꢀreplacement
ꢀ FuseꢀdrawerꢀmeetsꢀrequirementsꢀofꢀmedicalꢀstandardꢀIEC/ENꢀ60601-1
ꢀ Theꢀfuseholderꢀisꢀaccessibleꢀfromꢀtheꢀequipmentꢀfront
-ꢀTechnicalꢀdataꢀofꢀfilter-componentsꢀseeꢀblockfilterꢀtypeꢀ5500
-ꢀFullyꢀinsulatedꢀfromꢀtheꢀrear
ꢀ Snap-InꢀVersionꢀfromꢀfrontꢀsideꢀ
-ꢀ2ꢀ-ꢀ5ꢀFunctions:
ꢀ InletꢀProtectionꢀclassꢀI,ꢀOutlet,ꢀLineꢀswitchꢀ2-pole,ꢀFuseholderꢀforꢀfuse-
linksꢀ5ꢀxꢀ20ꢀmmꢀ1-ꢀorꢀ2-pole,ꢀLineꢀfilterꢀinꢀstandardꢀandꢀmedicalꢀver-
sionꢀ
-ꢀSolderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀ
mmꢀ
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950
-ꢀAlternative:ꢀversionꢀwithoutꢀlineꢀfilterꢀꢀFelcomꢀ64ꢀ
Other versions on request
-ꢀLineꢀswitchꢀwithꢀotherꢀrockerꢀmarking
Approvals
-ꢀVDEꢀLicenseꢀNumber:ꢀ101307
-ꢀULꢀLicenseꢀNumber:ꢀE72928
References
GeneralꢀProductꢀInformation
Weblinks
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀe-Store,ꢀSCHURTER-Stock-Check,ꢀ
Distributor-Stock-Check
Technical Data
RatingsꢀIEC
RatingsꢀUL/CSA
LeakageꢀCurrent
1ꢀ-ꢀ6ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250ꢀVAC;ꢀHzꢀ50
1ꢀ-ꢀ6ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ125ꢀVAC;ꢀ60ꢀHz
standardꢀ<ꢀ0.5ꢀmAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)ꢀ
medicalꢀ<ꢀ5ꢀµAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)
>ꢀ1.7ꢀkVDCꢀbetweenꢀL-Nꢀ
>ꢀ2.7ꢀkVDCꢀbetweenꢀL/N-PEꢀ
Testꢀvoltageꢀ(2ꢀsec)
-25ꢀ°Cꢀtoꢀ85ꢀ°C
25/085/21ꢀacc.ꢀtoꢀIECꢀ60068-1
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ
classꢀIꢀacc.ꢀtoꢀIECꢀ61140
Solderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀ
connectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm
Snap-in:ꢀ1/1.2/1.5/2/2.5/3ꢀmm
Thermoplastic,ꢀblack,ꢀULꢀ94V-0
Appliance-Inletꢀ/-Outlet
Fuseholder
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ
Fꢀacc.ꢀtoꢀIEC/ENꢀ60320-2-2,ꢀ
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ
condition)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10ꢀA,ꢀ
ProtectionꢀclassꢀI
1ꢀorꢀ2ꢀpole,ꢀShocksafeꢀcategoryꢀPC2ꢀ
acc.ꢀtoꢀIECꢀ60127-6,ꢀ
forꢀfuse-linksꢀ5ꢀxꢀ20ꢀmm
DielectricꢀStrength
AllowableꢀOperationꢀTemp.
ClimaticꢀCategory
DegreeꢀofꢀProtection
ProtectionꢀClass
RatedꢀPowerꢀAcceptanceꢀ@ꢀ 5ꢀxꢀ20:ꢀ2ꢀWꢀ(1ꢀpole)/ꢀ1.6ꢀWꢀ(2-pole)ꢀperꢀ
Taꢀ23ꢀ°C
PowerꢀAcceptanceꢀ@ꢀTaꢀ>ꢀ
23°C
pole
Admissibleꢀpowerꢀacceptanceꢀatꢀhig-
herꢀambientꢀtemperatureꢀseeꢀderatingꢀ
curves
Rockerꢀswitchꢀ2-pole,ꢀnon-illuminated,ꢀ
acc.ꢀtoꢀIECꢀ61058-1ꢀ
Terminal
LineꢀSwitch
LineꢀFilter
PanelꢀThicknessꢀs
Material:ꢀHousing
Technicalꢀdetails
StandardꢀVersion,ꢀIECꢀ60939,ꢀIECꢀ
60601-1,ꢀULꢀ1283,ꢀULꢀ544,ꢀENꢀ133ꢀ
200,ꢀCSAꢀC22.2ꢀno.ꢀ8ꢀ
Technicalꢀdetails
MTBF
>ꢀ1'400'000ꢀhꢀacc.ꢀtoꢀMIL-HB-217ꢀF
EMC products
ꢀ