50ACP_S Series
50W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
50 Watt
High efficiency up to 88.5%
Universal AC input range
(90~264VAC)
Wide operating ambient
temperature (-25°C~70°C)
Operating altitude up to
5000M
100% full load burn-in test
Easy assembling from top
side
PCB soldering side with
conformal coating
The 50ACP_S series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installa-
tion (35mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
Withstand 300VA surge input
for 5 sec.
Over voltage protection (OVP)
Over load protection (OLP)
Short circuit protection (SCP)
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40°C MAX
Input voltage range
Input frequency
AC current
88~264VAC, 127~370VDC
47~63Hz
1.3A (max)
Free air convection
-25°C~+70°C
Inrush current
Cold start,
230VAC
45A (max)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Safety standards:
-40°C ~+85°C
Leakage current
(input 264Vac, 63Hz)
Input—output: <0.25mA
Input—PG: <3.5mA
< 95%
0.03%/°C MAX
+25°C >200,000 hours
Output specifications
UL60950-1 2nd Ed; IEC 60950-1:2005 (2nd
Ed); EN60950-1:2006
Item
Test conditions
Full load
Min Typ
Max
3
Units
%
Output voltage
accuracy
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
Voltage adjustment •5V: 4.75~5.5V
Dimensions (L*W*H):
Weight:
99×82×35mm
320g
range
•12V: 11.4~13.2V
•15V: 14.25~15V
•24V: 22.8~26.4V
•48V: 45.6~52.8V
Isolation specifications
Line regulation
Vin= min. to max. at
full load
0.5
%
Item
Test condition
Min
Typ
Max
Units
VAC
Load regulation
Set-up time
0% to 100% load
1
%
s
Withstand voltage*
• Primary-Sec.: 10mA
• Primary-PG: 10mA
• Secondary-PG: 10mA
3000
1500
500
@230VAC input, full
load
1.5
Isolation resistance
100
MΩ
Hold-up time
(full load)
@230VAC input
50
ms
%
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
Overshoot and
undershoot
5
Protection specifications
Switching fre-
quency
100
KHz
Over-load
protection
•5V: 8.4~12A
Protection type:
•12V: 4.41~6.3A
•15V: 3.57~5.1A
•24V: 2.31~3.3A
•48V: 1.155~1.65A
5V is hiccup mode, rest
are constant power, auto
recovery
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Example:
50ACP_24S
Over-voltage
protection
•5V: 5.75~7.5V
•12V: 13.8~18V
•15V: 17.25~22.5V
•24V: 27.6~36V
•48V: 55.2~72V
Protection type:
constant voltage, auto
recovery
50 = 50Watt
AC = AC-DC
P = series
24 = 24 Vout
S = single output
Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25°C of ambient temperature.
Page 1 of 3
50ACP_S – Rev. 2020-1.2
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com