Power Transformers
Horizontal
4766 - 4770
LOW VOLTAGE RECTIFIER Transformer
with horizontal channel frames.
·
·
·
·
Primary voltage,115 Volts, 60 Hz.
Primary and secondary leads 8-10" long.
2-hole horizontal mounting.
5 sizes are available, covering the range:
10 to 50 VA.
·
CSA listed (LR 47366).
MECHANICAL
Dimensions, Inches
DIMENSIONS
PIN SPACING
P/N
L
W
H
A
4766
4767
4768
4769
4770
3.25
3.25
3.69
4.00
4.00
2.00
2.25
2.13
2.25
2.50
2.00
2.00
2.31
2.63
2.63
2.81
2.81
3.13
3.56
3.56
ELECTRICAL SPECIFICATION
Secondary Voltages (A-A)
Secondary Voltages (A-A)
F.L.
N.L.
Current
Amps
F.L.
Volts
N.L.
Current
Part No.
Volts
Volts
Part No.
Volts
Amps
4766-01
4766-02
4766-03
4766-04
4766-05
4766-06
4766-07
4766-08
4766-09
4766-10
6.3
6.3
7.25
7.14
1.20
2.00
1.00
1.00
0.50
0.50
0.50
0.30
0.25
0.30
4769-01
4769-02
14.0
18.0
15.30
19.60
2.00
1.50
10.0
14.0
20.0
28.0
30.0
36.0
44.0
50.0
11.00
16.00
22.00
32.00
34.20
39.40
50.60
57.00
4770-01
4770-02
4770-03
4770-04
4770-05
4770-06
4770-07
4770-08
4770-09
4770-10
4770-11
4770-12
4770-13
4770-14
8.5
10.0
16.0
16.0
20.0
25.0
33.0
36.0
44.0
50.0
60.0
80.0
100.0
120.0
9.04
10.50
17.00
17.40
21.40
26.80
35.00
39.50
47.40
54.50
65.20
85.50
107.00
129.50
4.00
3.00
2.20
3.00
2.00
1.50
1.00
1.00
1.00
1.00
0.50
0.50
0.50
0.30
4767-01
4767-02
4767-03
8.5
36.0
16.0
9.60
40.00
17.60
2.00
0.50
1.00
4768-01
4768-02
4768-03
4768-04
4768-05
4768-06
4768-07
4768-08
4768-09
6.3
8.5
6.90
9.50
4.00
3.00
2.00
2.00
1.00
1.00
1.00
0.50
0.50
10.0
12.6
20.0
25.0
28.0
44.0
50.0
10.80
13.80
22.00
27.50
30.80
48.10
55.00
229 Colonnade Road, Nepean, Ontario, Canada K2E 7K3
Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com
An ISO 9001 Registered Company