High Temperature – Very Low ESR – High Ripple Current –
Stable with Temperature – High Frequency
FEATURES
DC-DC Converters – Voltage Regulators – Decoupling
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-55°C to +105°C
+20% at 120 Hz, 20°C
WVDC
SVDC
2.5
4
6.3
10
16
Surge Voltage
1.15 x rated WVDC
Dissipation Factor
120 Hz, 20°C
12% MAX
2 Minutes
0.2CV or 280uA, whichever is greater
Leakage Current
Low Temperature Stability
Impedance Ratio
(100 kHz)
-55°C/ +20°C
<1.25
<1.25
+105°C/ +20°C
2000 hours at 105°C with rated WVDC applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
ESR
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Load Life
Leakage Current
1000 hours at 60°C with rated voltage applied at 90-95% R.H.
Capacitance Change
<20% of initial measured value
Dissipation Factor
ESR
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Damp Heat test
Leakage Current
Capacitors placed on a 230°C hot plate for 75 seconds with their electrode terminations facing
downward will fulfill the following conditions after being cooled to room temperature
Capacitance Change
Dissipation Factor
ESR
<20% of initial measured value
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Resistance to Soldering Heat
Leakage Current
Ripple Current Multipliers
120Hz<f<1kHz
0.05
1kHz<f<10kHz 10kHz<f<100kHz 100kHz<f<500kHz
0.3
0.7
1.0
Special Order Options
D+0.5 W+0.2
H+0.2
LL+0.2 R+0..15
S+0.2
6.3
8
10
6.6
8.3
10.3
6.6
8.3
10.3
2.1
2.8
3.1
.65
.95
.95
1.9
3.2
3.5
Nov-22