Surface Mount Fuse Datasheet
422A Series
AEC-Q200 Qualified > Ceramic Fuse
P
S
E
RoHS Pb
Description
The 422A is a 250V rated Wire-in-Air Surface Mount, AEC-
Qualified fuse. They are specifically tested to cater to secondary
circuit protection needs of compact auto electronics applications.
The wire-in-air design of the 422A Series results in a relatively high
I2t in a 2410 size.
The general design ensures excellent temperature stability and
performance reliability.
Features & Benefits
■ OperatingTemperature
■ Avoids nuisance opening
due to high inrush and surge
current inherent in the
system
from -55 °C to 125 °C
■ 100% Lead-free, Halogen-
free and RoHS compliant
■ Suitable for harsh automotive
environments
■ Fast acting
■ Recognized to UL/CSA/NMX
248-1 and UL/CSA/NMX
248-14
Additional Information
■ Qualified to AEC-Q200
■ Conforms to EN/IEC 60127-1
and EN/IEC 60127-7
■ Conforms to J60127-1 and
J60127-7
Resources
Accessories
Samples
Applications
■ Li-ion Battery
■ Battery Management System
(BMS)
Agency Approvals
■ LED Lighting Automotive
Navigation System
■ Instrument Cluster
Agency
Agency File/Certificate Number
Ampere Range
E10480
J50501694
JD60156347
NA
0.75 A to 5 A
0.75 A to 5 A
0.75 A to 5 A
0.75 A to 5 A
0.75 A to 5 A
Electrical Characteristics
% of Ampere Rating
Ampere Rating
Opening Time
P
S
E
100%
200%
0.75 A to 5 A
0.75 A to 5 A
4 Hours, Minimum
NA
5 Seconds, Maximum
Electrical Specifications
Ampere
Rating
(A)
Max
Voltage
Rating (V)
Interrupting
Nominal
Nominal
Melting
Agency Approvals
Amp
Code
Rating
Resistance
P
S
(AC/DC) 1, 4
(Ohms) 2
I2t (A2sec) 3
E
300 A @ 32 VDC
100 A @ 125 VDC
50 A @ 250 VAC
50 A @ 250 VDC
0.750
1.00
1.25
1.50
2.00
2.50
3.00
3.15
3.50
4.00
5.00
.750
001.
1.25
01.5
002.
02.5
003.
3.15
03.5
004.
005.
250
250
250
250
250
125
125
125
125
125
125
0.137
0.0994
0.0734
0.0589
0.0453
0.0278
0.0223
0.0213
0.0192
0.0168
0.0137
0.282
0.611
1.09
1.62
2.85
1.29
2.09
2.40
2.82
3.60
5.90
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
--
x
x
x
x
x
x
x
x
x
x
x
x
x
10,000 A @ 86 VDC
300 A @ 32 VDC
100 A @ 125 VDC
50 A @ 125 VAC
Notes
1. AC Interrupting Rating tested at rated voltage with unity power factor. DC Interrupting Rating tested with time constant <0.8 ms for 32 VDC, <2.2 ms for 86 VDC, <0.22 ms for 125 VDC, and <0.1 ms for 250 VDC.
2. Nominal Resistance measured with <10% rated current.
3. Nominal Melting I2t measured at 1 msec. opening time.
4. Interrupting Rating may differ based on Agency Approval. See Agency Approval certificate for more details.
© 2023 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: GD. 05/24/23
1