420LB28 - 420LE60
Only One Name Means ProTek’Tion™
TWO LINE PAIR 4ꢀ20mA CONTROL LOOP PROTECTOR
DEꢁCRIPTION
The 420LE/B series is a two stage transient voltage protector providing primary and secondary protecꢀon against
lightning, inducꢀve switching and electrostaꢀc discharge (ESD) transient threats. The first stage diverts the transient
current through the ground terminal return path and the second stage clamps the voltage to a safe level without inter-
rupꢀon of service.
The 420LE/B series is designed to protect data lines from differenꢀal (line to line) and common mode (line to ground)
transients. Terminals 1 and 2, 3 and 4 for the 420LE and pins 2 and 3, 4, and 5 for the 420LB are designated as line
pairs. Each line pair is referenced to ground. A transient voltage suppressor is connected across each line pair for dif-
ferenꢀal mode protecꢀon. Each line pair is referenced to ground.
420LB
420LE
This product can also be used on telephone, signal/data lines, security, ꢀming and control interface circuits. For most
applicaꢀons, the product should be located as close as possible to the equipment being protected. A low impedance
grounding system is important to maintain a low voltage clamp between the line-to-ground connecꢀon.
FEATuREꢁ
APPLICATIONꢁ
• Compaꢀble with IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
• Compaꢀble with IEC 61000-4-4 (EFT): 40A - 5/50ns
• Compaꢀble with IEC 61000-4-5 (Surge): 95A, 8/20µs, Level 4 (Line-
Gnd) & 48A, Level 4 (Line-Line)
• Mulꢀ-Process Control Loops
• Fire & Security Systems
• Petro-Chemical Plants
• Refineries & Tank Farms
• Designed for 4-20mA Current Loops
• Automaꢀc Reset - Does Not Interrupt Service
• Permanent Two-Stage Line Pair Protecꢀon
• Common Mode & Differenꢀal Mode Protecꢀon
• Subnanosecond Response Time
• Effecꢀve Against Lightning, Inducꢀve Switching and ESD
MEChANICAL ChARACTERIꢁTICꢁ
• Approximate Weight: 28 grams (420LB) & 142 grams (420LE)
• Flammability Raꢀng UL 94V-0
www.protekdevices.com