描述
Universal two-wire Transmitter

405000 数据手册

 浏览型号405000的Datasheet PDF文件第2页 
4. MOUNTING  
INSTRUCTION  
MANUAL  
The 405000 can be mounted in  
connection heads with a distance  
between holes of 1.30 to 1.81 in.  
(33 mm to 46 mm.) #6 (M4)  
screws with a maximum head  
diameter of 0.27 in (6.8 mm)  
should be used  
Model 405000  
Universal two-wire Transmitter  
5. INSTALLATION  
J/K thermocouple or RTD inputs  
Configurable INPUT and RANGE  
4 - 20mA two-wire output connection  
A) Check that the temperature probe’s measurement range matches the  
range for which the 405000 is configured. To reconfigure see  
Sections 7 and 8.  
B) The mounting head must have a distance of 1.30 in (33 mm.) min.  
between holes. The internal diameter of the housing must be at least  
1.69 in (43 mm).  
Eliminates the need for compensation  
& extension wire  
C) For heads with 1.69 in. (43 mm) diameter housings, cut the screw  
slots. For bigger heads, cutting is not necessary. (Fig. 3).  
D) Mount the 405000 so that the wires easily fit through the base and so  
that the signal cable can fit through the opening between the lid and  
the body.  
ABS plastic rugged construction  
1. INTRODUCTION  
E) Assure the polarity of the sensor wires and of the signal line and  
check that the screws of the terminal block are tight.  
Congratulations on your purchase of Extech’s 405000 Universal Two-  
wire Transmitter. This professional device, with proper care, will provide  
years of safe reliable service. The Model 405000 is a configurable 2-wire  
4-20 mA output temperature transmitter for mounting in thermocouple or  
RTD connection heads or on its own (indoor use only).  
CAUTIONS: Avoid loose wires that could  
touch the solder jumpers. Replace the  
protective cover before closing the  
2. SPECIFICATIONS  
connection head. Avoid corrosive steam,  
leaks or direct moisture, use at least IP-54  
heads (NEMA 3). Avoid temperatures over  
125 °F (50 °C). Avoid vibrations and protect  
from electro-magnetic radiation, radio  
frequencies, microwaves, high voltage, etc.  
Input  
J , K thermocouples, Pt 100RTD (Section 8)  
4-20mA two-wire  
Output  
Input impedance  
Excitation current  
Circuit break protect  
Power supply  
Load capability  
1 Mohm  
0.23mA  
Upscale >30mA  
12 to 45VDC (polarity protected)  
600 ohms max. at 24V  
0.1% full scale  
6. WIRING  
VERY IMPORTANT: Check that the  
temperature probe’s measurement  
range matches the range for which  
the 405000 is configured. In the  
event that reconfiguration is  
Accuracy J or K  
thermocouple  
Accuracy RTD  
Linearity  
0.1 to 0.25% full scale  
0.06% full scale  
necessary see Sections 7 and 8.  
Open the 405000 by removing the lid  
(Fig. 4) to access the terminal block.  
Refer to Fig. 5 and the text below for  
terminal connection information.  
Calibration  
Zero and Span potentiometer adjustments  
± 0.02% / oC  
Zero drift  
Voltage supply effect  
± 0.002% / V  
32 to 122oF (0 to 50oC)  
Cold junction  
compensation  
RTD Pt 100 sensors:  
Operating temperature  
RFI immunity  
-4 to 158oF (-20 to 70oC)  
CE certified  
3-wire: Connect RTD to terminals 1, 2 and 3 (RTD common wires  
connect to 1 and 3))  
4-wire: Leave one wire unconnected and connect as a 3-wire sensor  
described above.  
Housing and rating  
Dimensions  
ABS plastic with protective cover, Nema 2 (IP-42)  
1.7” (43mm) dia., 1” (26mm) high  
1.3” (33mm) to 1.9” (49mm)  
0.8oz. (25g)  
2-wire: Connect RTD to terminals 2 and 3 (short terminals 1 and 3).  
THERMOCOUPLE Sensors:  
Mounting holes  
Weight  
Connect thermocouples to terminal 1 (-) and terminal 2 (+)  
IMPORTANT: Connect the thermocouple wire directly to the 405000  
terminals or use thermocouple extension wire for the given type of  
thermocouple if necessary.  
3. DESCRIPTION  
NOTE: Do not ground the temperature sensor and the power supply.  
Ground only one or the other to avoid ground loop errors.  
1. Protective Cover  
2. Mounting hole  
4-20mA Output: Available on terminals 5 (--) and 4 (+).  
Status LED: As the input to the transmitter increases so does the  
3. Zero/Span  
intensity of the red LED.  
Potentiometers  
Typical Application:  
4. Wire connections  
5. Range solder bridges  
6. Circuit removal screw  
Wiring for a typical temperature  
transmitter application.  
7. LED (increases  
intensity as transmitter  
output increases)  
405000  
Ver. 1.2 5/03  

与405000相关器件

型号 品牌 描述 获取价格 数据表
405006A10M050 MOLEX Circular Connector,

获取价格

405006A10M060 MOLEX Circular Connector,

获取价格

405006B09M020 MOLEX Circular Connector,

获取价格

405006D12M010 MOLEX Circular Connector,

获取价格

4050B FAIRCHILD Hex Inverting Buffer . Hex Non-Inverting Buffer

获取价格

4050BDC FAIRCHILD Buffer, CMOS, CDIP16,

获取价格