5秒后页面跳转
401017 PDF预览

401017

更新时间: 2024-11-28 06:26:59
品牌 Logo 应用领域
EXTECH /
页数 文件大小 规格书
1页 45K
描述
Big Digit Window Thermometer

401017 数据手册

  
Operation  
User’s Guide  
Attention: The LCD display is delicate. When removing the  
thermometer from a window pull only with the plastic  
housing. Do not pull with or bend the display.  
Installation  
1. Clean the outside of the window where the thermometer is  
going to be installed. Wipe until the surface is dry.  
Big Digit Window  
Thermometer  
Model 401016 and 401017  
2. Pull off the protection foil on the display  
3. Peel back the two red adhesive cover strips located at the  
top of each end of the thermometer  
4. Press the thermometer against the clean outside window for  
15 to 30 seconds to affix  
Measuring range:  
-13°F ~ +158°F  
Mode  
+
Max/Min Temperature  
The Maximum and Minimum temperature is displayed above and  
below the main temperature display. These displays are updated  
each time a new high or low temperature is measured.  
The MAX and MIN displays are automatically reset every 24  
hours. The maximum temperature is reset at 8:00 AM and  
minimum temperature at 8:00 PM (20:00). Therefore, the current  
time must be set for the Max/Min displays to work properly  
Setting the Time  
1. Remove the thermometer from its holder  
2. Press the MODE button and the hour digits will begin to flash  
3. Use the “+” button to set the hours. Hold and press the button  
for a fast count  
4. Press the MODE button again the minute digits will flash  
5. Use the “+” button to set the minutes  
Introduction  
6. Press the MODE button to return to normal operation  
UV Shield installation:  
Congratulations on your purchase of Extech’s Big Digit Window  
Thermometer. It can be used to monitor temperature outside, in  
controlled rooms, laboratories or other temperature stabilized areas. It  
features Min/Max display with an auto reset. This meter is shipped  
fully tested and calibrated and, with proper use, will provide years of  
reliable service.  
The UV shield is included to protect the display when it is  
exposed to direct sunlight for extended periods and it also  
improves readability at night. To install the shield, slide it up  
behind the display and press until it snaps into place.  
Maintenance  
Specifications  
Clean the thermometer with a soft damp cloth. DO NOT use chemicals,  
cleaning solvents, or detergents.  
Temperature  
-13 to 158ºF (Model 401016)  
-25 to 70ºC (Model 401017)  
±1.8ºF/1ºC  
0.1ºF/0.1ºC  
One (1) ‘AAA’ 1.5V Battery  
4 x 3.83 x 0.8” (103 x 97 x 20mm)  
Accuracy  
Resolution  
Battery  
Battery Replacement  
Remove the thermometer from the holder. Remove the Phillips screw  
to access the battery compartment. Replace the 1.5V ‘AAA’ battery and  
secure the battery cover.  
Dimensions  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants the basic  
instrument to be free of defects in parts and workmanship for one year  
from date of shipment (a six month limited warranty applies on sensors  
and cables). If it should become necessary to return the instrument for  
service during or beyond the warranty period, contact the Customer  
Service Department at (781) 890-7440 EXTENSION 210 for  
authorization or visit www.extech.com for more information. A Return  
Authorization (RA) number must be issued before any product is  
returned to Extech. The sender is responsible for shipping charges,  
freight, insurance and proper packaging to prevent damage in transit.  
This warranty does not apply to defects resulting from action of the user  
such as misuse, improper wiring, operation outside of specification,  
improper maintenance or repair, or unauthorized modification. Extech  
specifically disclaims any implied warranties or merchantability or  
fitness for a specific purpose and will not be liable for any direct,  
indirect, incidental or consequential damages. Extech's total liability is  
limited to repair or replacement of the product. The warranty set forth  
above is inclusive and no other warranty, whether written or oral, is  
expressed or implied.  
Support line (781) 890-7440  
Technical support: Extension 200; E-mail: support@extech.com  
Repair & Returns: Extension 210; E-mail: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User’s Guide, Software updates, and other  
up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation 285 Bear Hill Rd Waltham MA 02451  
Copyright © 2007 Extech Instruments Corporation. All  
rights reserved including the right of reproduction in  
whole or in part in any form.  
V2.1 07/07  

与401017相关器件

型号 品牌 获取价格 描述 数据表
40101C MURATA

获取价格

Toroidal Surface Mount Inductors
401020 EXTECH

获取价格

Light Meter Adapters
401021 EXTECH

获取价格

Light Meter Adapters
401025 EXTECH

获取价格

Digital Light Meter
401027 EXTECH

获取价格

Pocket Foot Candle Light Meter
40102F EXTECH

获取价格

Recording Indoor/Outdoor Thermometer Clock
40-10-31 APITECH

获取价格

Fixed Attenuator
40-10-32 APITECH

获取价格

RF/MICROWAVE FIXED ATTENUATOR
401036 EXTECH

获取价格

Datalogging Light Meter with PC Interface
40-10-43-LIM APITECH

获取价格

Fixed Attenuator, 0MHz Min, 1500MHz Max