描述
Indoor / Outdoor Temperature Alarm

401012 数据手册

  
INSTRUCTION MANUAL  
Model 401012 Indoor / Outdoor Temperature Alarm  
1. POSITIONING THE OUTSIDE SENSOR  
3. Press HI SET until the desired high setpoint is selected.  
Press and hold this key for rapid digit scrolling.  
4. Press LO SET until the desired low setpoint is selected. Press  
and hold this key for rapid digit scrolling.  
Position the outside sensor away from direct sunlight and severe  
precipitation. The indoor sensor is built into meter faceplate (top).  
2. MOUNTING  
5. Press the ALERT ON/OFF button to turn on the temperature  
alert ("ALERT" appears in the lower right hand corner of the  
display).  
The Temperature Alarm has a folding stand on the rear for desktop  
display. A wall mounting bracket is supplied which may be used  
with double sided tape or screws (both included).  
3. ONE POINT TEMPERATURE CONTROL  
6. Move the slide switch downward to the TEMP position after  
setting temp. alert.  
7. The alarm sounds (& status LEDs flash) every min. (on the  
min.) that the temperature is higher than the high setpoint or  
lower than the low setpoint.  
3.1 High Temperature Alert (Outdoor Temperature Only)  
1. Move the slide switch upward to the ALERT position.  
2. Press ALERT SELECT until the high temperature alert mode,  
"•", is selected.  
5. DISABLING THE TEMPERATURE ALERT  
With the slide switch in the ALERT position, press ALERT ON/OFF  
until "ALERT" disappears from the lower right hand corner of the  
display.  
3. Press HI SET until the high temperature setpoint is selected.  
Press and hold this key for rapid digit scrolling.  
4. Press the ALERT ON/OFF button to turn on the high  
temperature alert ("ALERT" appears in the lower right hand  
corner of the display).  
6. FRONT PANEL DESCRIPTION  
5. Move the slide switch downward to the TEMP position after  
setting temp. alert.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
10  
Indoor Temp.  
Outdoor Temp.  
Alert ON/OFF  
Alert Select  
6. The alarm sounds and the status LEDs flash every minute (on  
the minute) that the measured temperature remains higher  
than the setpoint.  
High Temp.  
3.2 Low Temperature Alert (Outdoor Temperature Only)  
1. Move the slide switch upward to the ALERT position.  
2. Press ALERT SELECT until the low temperature alert  
mode,"– ", is selected.  
Low Temp.  
Temp. Alert  
Status LEDs  
Sensor cable  
Exterior sensor  
3. Press LO SET until the low temperature setpoint is selected.  
Press and hold this key for rapid digit scrolling.  
4. Press the ALERT ON/OFF button to turn on the low  
temperature alert ("ALERT" appears in the lower right hand  
corner of the display).  
7. BATTERY REPLACEMENT  
5. Move the slide switch downward to the TEMP position after  
setting the temp. alert.  
Lift up the battery cover on rear and replace the “AAA” cell keeping  
the new battery’s orientation the same as the old one.  
6. The alarm sounds and the status LEDs flash every minute (on  
the minute) that the measured temperature remains lower  
than the setpoint.  
8. WARRANTY  
4. TWO POINT TEMPERATURE CONTROL  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of  
defects in parts and workmanship for one year from date of shipment (a six month  
limited warranty applies on sensors and cables). If it should become necessary to  
return the instrument for service during or beyond the warranty period, contact the  
Customer Service Department at (781) 890-7440 ext. 210 for authorization. A  
Return Authorization (RA) number must be issued before any product is returned  
to Extech. The sender is responsible for shipping charges, freight, insurance and  
proper packaging to prevent damage in transit.  
This warranty does not apply to defects resulting from action of the user such as  
misuse, improper wiring, operation outside of specification, improper maintenance  
or repair, or unauthorized modification. Extech specifically disclaims any implied  
warranties or merchantability or fitness for a specific purpose and will not be liable  
for any direct, indirect, incidental or consequential damages. Extech's total liability  
is limited to repair or replacement of the product.  
4.1 Alarm when measured temperature is between the two  
setpoints (Outdoor Temperature Only)  
1. Move the slide switch upward to the ALERT position.  
2. Press ALERT SELECT until the "  
", is selected.  
3. Press HI SET until the desired high setpoint is selected.  
Press and hold this key for rapid digit scrolling.  
4. Press LO SET until the desired low setpoint is selected. Press  
and hold this key for rapid digit scrolling.  
5. Press the ALERT ON/OFF button to turn on temperature alert  
("ALERT" appears in the lower right hand corner of the  
display).  
6. Move the slide switch downward to the TEMP position after  
setting temp. alert.  
The warranty set forth above is inclusive and no other warranty, whether written  
or oral, is expressed or implied.  
7. The alarm sounds and the status LEDs flash every minute (on  
the minute) that the measured temperature is between the  
setpoints.  
Copyright © 1999 Extech Instruments Corporation.  
All rights reserved including the right of reproduction in  
whole or in part in any form.  
4.2 Alarm when measured temperature is beyond the two  
setpoints (Outdoor Temperature Only)  
1. Move the slide switch upward to the ALERT position.  
2. Press ALERT SELECT until the, "  
", is selected.  
1
401012  
Ver. 1.4 12/00  

与401012相关器件

型号 品牌 获取价格 描述 数据表
401014 EXTECH

获取价格

Big Digit Indoor/Outdoor Thermometer
4010-15M ETC

获取价格

Interface IC
401016 EXTECH

获取价格

Big Digit Window Thermometer
401017 EXTECH

获取价格

Big Digit Window Thermometer
40101C MURATA

获取价格

Toroidal Surface Mount Inductors
401020 EXTECH

获取价格

Light Meter Adapters
401021 EXTECH

获取价格

Light Meter Adapters
401025 EXTECH

获取价格

Digital Light Meter
401027 EXTECH

获取价格

Pocket Foot Candle Light Meter
40102F EXTECH

获取价格

Recording Indoor/Outdoor Thermometer Clock