Multiple Case Sizes - High Voltage High Current
FEATURES
–
Filtering Switching Power Supplies
APPLICATIONS
–
Operating Temperature
Range
-40°C to +85°C (10VDC to 250VDC)
-25°C to +85°C (350VDC to 500VDC)
+20% at 120 Hz, 20°C
Capacitance Tolerance
10
16
25
35
50
63
80
100
160
200
250
350
400 450
500
WVDC
Surge Voltage
13
20
32
44
63
79 100
120
200
250
300
400
450 500
550
SVDC
WVDC
10
16
25
35
50
63
80
100
160
200
250
350
400 450
500
Dissipation
Factor
(120 Hz)
.55
.5
.45
.4
.35
.3
.25
.2
.15
.15
.15
.15
.15
.2
.2
tan δ
For capacitance values above 33000μF
the following to the Dissipation factors values above
(capacitance-33000 μF)*0.1 add
10000 μF
Leakage Current
@20°C, Rated WVDC
applied
5 Minutes
3√CV
Time
10
16
25
35
50
63
80 100 160 200
250
350
400
450
500
Impedance
Ratio
WVDC
-25°C/+20°C
4
4
4
4
4
4
4
4
3
3
3
3
8
8
8
(120 Hz)
-40°C/+20°C
15
15
15
15
15
15
15
15
15
15
15
-
-
-
-
2000 hours with rated voltage applied at 85°C with full rated ripple current applied
Capacitance Change
Dissipation Factor
Leakage Current
<20% of initial measured value
Load Life
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
Leakage Current
Shelf Life
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
WVDC
60
120
1k
10k
Ripple Current
Multipliers
10 to 100
160 to 250
350 to 500
0.9
0.8
0.8
1.0
1.0
1.0
1.15
1.15
1.15
1.25
1.47
1.47
Dec-21