描述
Capacitance Decade Box

380405 数据手册

  
User Guide  
Capacitance Decade Box  
Model 380405  
Introduction  
Congratulations on your purchase of the Extech 380405 Capacitance Decade Box. This device  
offers 5 decades of capacitance ranges from 100pF to 11.111uF (in 100pF steps). Slide switches  
allow easy addition and subtraction of capacitance values. Binding posts (3) offer simple and secure  
connections. Careful use of this decade box will provide years of reliable service.  
Specifications  
Capacitance ranges  
Internal Residual Cap:  
Voltage limit  
Connection  
Accuracy  
Operating conditions  
Dimensions/Weight  
100pF to 11.111uF in 100pF steps  
50pF maximum  
50VDC (non-polarized capacitors)  
Three (3) binding posts  
5% (< 1uF: 1kHz test frequency; > 1uF: 100Hz test frequency)  
Temperature: 32 to 122oF (0 to 50oC) / Humidity: < 80%RH  
5.79 x 4.61 x 1.3" (14.7 x 11.7 x 3.3cm) / Approx. 0.69 lbs. (312g)  
Operation  
Binding Post Connections  
The binding posts can be used for connections in several ways:  
1. A banana plug can be inserted directly into the posts.  
2. Bare wire can be threaded through the post after it has been unscrewed. Once the bare wire is threaded, tighten the posts as necessary.  
3. Alligator clips can be used but use caution not to strip the post threads or plastic post housing.  
The Capacitance output is available on the RED and the BLACK binding posts. The WHITE post is case ground and is typically not used. Connect the  
positive lead of the device under test to the RED post. Connect the negative lead to the BLACK post. Use the WHITE grounding post only if the device  
under test will be grounded to the 380405 case.  
Range Selection  
The 20 front panel switches are used to select the capacitance that will be output on the RED and BLACK terminals. When a switch is set to the IN  
position, the value printed above the switch is added to the total capacitance available at the posts. When the switch is set to OUT it is excluded from  
the total capacitance. If all of the switches are set to OUT, the total output capacitance will be zero (+ 50pF residual capacitance – approx).  
For example, if the desired output value is 10.5uF, set the following switches to the IN position: 4uF, 3uF, 2uF, 1uF, 0.4uF, and 0.1uF.  
Testing  
This device can be used to verify the calibration integrity of multimeters, LCR meters, calibrators, etc. Connect as described in the Binding Post  
Connections section above, and then set the capacitance switches to output the desired capacitance. Ensure that the voltage supplied by the device  
under test is not greater than 50VDC. The device under test should read the value of capacitance selected on the tester. If it does not, the device  
under test may need calibration, adjustment, or repair.  
Calibration and Repair Services  
Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification on most products  
or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an  
annual basis to ensure calibration integrity.  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty  
applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department  
at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on ‘Contact Extech’ and go to ‘Service Department’ to request an RA number). A Return  
Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to  
prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper  
maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for  
any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no  
other warranty, whether written or oral, is expressed or implied.  
Copyright © 2002 Extech Instruments Corporation.  
All rights reserved including the right of reproduction in whole or in part in any form.  
Model 380405 Version 1.1 August 2002  

与380405相关器件

型号 品牌 获取价格 描述 数据表
38041 ALTECH

获取价格

ONE PHASE POWER DISTRIBUTION BLOCKS
38041K1206 SWITCH

获取价格

Multi Switch, DPDT, Latched, Screw Terminal, Panel Mount,
38041K1212 SWITCH

获取价格

Multi Switch, 4PDT, Latched, Screw Terminal, Panel Mount,
380421206 SWITCH

获取价格

Multi Switch, DPDT, Momentary, Screw Terminal, Panel Mount,
380421212 SWITCH

获取价格

Multi Switch, 4PDT, Momentary, Screw Terminal, Panel Mount,
380460 EXTECH

获取价格

Precision Milliohm Meters
380460_15 EXTECH

获取价格

Precision Milliohm Meter
380462 EXTECH

获取价格

Precision Milliohm Meters
380462_15 EXTECH

获取价格

Precision Milliohm Meter
380471206 SWITCH

获取价格

Multi Switch, DPDT, Latched, Screw Terminal, Panel Mount,