Polar
Small Size Non / Bi -
FEATURES
–
Audio Coupling Crossover Networks
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-40°C to +85°C
+20% at 120 Hz, 20°C
WVDC
6.3
10
16
25
35
50
63
100
Surge
Voltage
SVDC
WVDC
Tan δ
7.9
6.3
.28
13
10
.24
20
16
.22
32
25
.2
44
35
.16
63
50
.14
79
63
.12
125
100
.1
Dissipation
Factor
0.03CV + 3uA, after 2 minutes
Leakage Current
WVDC
6.3
4
10
10
3
8
16
2
6
25
2
5
35
2
4
50
2
4
63
2
3
100
2
3
Low temperature
Stability
Impedance Ratio
(120 Hz)
-25°C to 20°C
-40°C to 20°C
2000 hours at 85°C with rated WVDC and rated voltage reversed every 250 hours.
Capacitance Change
Dissipation Factor
Leakage Current
±20% of initial measured value
<200% of maximum specified value
>100% of maximum specified value
1000 hours at 85°C with no voltage applied
±20% of initial measured value
Load Life
Capacitance Change
Dissipation Factor
Leakage Current
Capacitance
Shelf Life
<200% of maximum specified value
<200% of maximum specified value
Frequency (Hz)
Temperature (°C)
µF
>68
100 to 470
60
.8
.75
.79
120
1.0
1.0
1.0
1k
>10k
1.65
1.53
1.45
+85
1.0
1.0
1.0
+70
1.3
1.3
1.3
+60
1.5
1.5
1.5
+30
1.8
1.8
1.8
1.45
1.36
1.3
Ripple Current Multipliers
<680
Special Order Options
.
D
d
S
5
0.5
2.0
6.3
0.5 0.6
2.5 3.5
8
10
0.6
5.0
12.5
0.6
5.0
16
0.8
7.5
18
0.8
7.5
L1=L+2.0mm Max.
D1=D+0.5 Max
S1=S+/-0.5 mm
Jun-22