APPLICABLE STANDARD
VOLTAGE
―
OPERATING
TEMPERATURE RANGE
STORAGE
TEMPERATURE RANGE
OPERATING
HUMIDITY RANGE
125 V AC
-30C TO +70C
-C TO -C
CURRENT
0.5 A
RATING
-%TO -%
APPLICABLE
CABLE
―
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
CONFIRMED VISUALLY.
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
1
mA (DC OR 1000 Hz).
40 m MAX.
250 M MIN.
X
X
X
X
X
X
INSULATION
100
V
DC.
RESISTANCE
VOLTAGE PROOF
300
V
AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
INSERTION AND
MEASURED BY APPLICABLE CONNECTOR.
INSERTION FORCE
WITHDRAWAL FORCE
20 N MAX.
2 N MIN.
WITHDRAWAL FORCES
X
-
MECHANICAL
OPERATION
3000 TIMES INSERTIONS AND EXTRACTIONS.
①CONTACT RESISTANCE : 60mMAX
②NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
X
X
-
-
VIBRATION
FREQUENCY 10 TO 55 Hz
SINGLE AMPLITUDE 0.75 mm
①NO ELECTRICAL DISCONTINUITY OF
5μs.
AT 2 h FOR
490 m/s2 DIRECTIONS OF PULSE 11 ms
AT TIMES FOR DIRECTIONS.
PULL THE CONNECTOR, CABLE AXIALY
3
DIRECTIONS.
②NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
SHOCK
-
-
X
X
3
6
LOCKING FORCE
40 N MIN.
ENVIRONMENTAL CHARACTERISTICS
TEMPERATURE
RAPID CHANGE OF
TEMPERATURE
NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
–55 → 5 TO 35 → +85 → 5 TO 35 C
TIME
X
X
-
-
30 → 2 TO 3 →30 →2 TO 3 min.
UNDER 5 CYCLES.
DAMP HEAT
(STEADY STATE)
EXPOSED AT 60 C, 90 TO 95 , 96 h
①INSULATION RESISTANCE :
AT HIGH HUMIDITY : 1 M MIN.
AT DRY
: 100 MMIN.
②NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
CORROSION SALT MIST
SOLDERABILITY
NO HEAVY CORROSION.
EXPOSED IN 5 SALT WATER SPRAY FOR
48 h.
X
X
-
-
SOLDERING POINT OF CONTACTS IMMERSION
IN SOLDER BATH OF 235 C±5 C, 2±0.5sec.
SOLDERING POINT OF CONTACTS
IMMERSION IN SOLDER 95% MIN.
SOLDERING CONDITION
(SOLDER IRON METHOD)
NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
TEMPERATURE : 350C±5 C,
TIME: 5±1 sec. MAX./pin
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NM.NISHIMATSU
NM.NISHIMATSU
P.EKSOURIYA
P.EKSOURIYA
16.07.07
16.07.07
16.07.07
16.07.07
Unless otherwise specified, refer to JIS C 5402 or IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-047967-60-01
3260-10S3(60)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
1/2
CL232-0047-5-60
△
FORM HD0011-2-1