Effective May 2017
Supersedes May 2014
Technical Data 2541
3216LV
Fast-acting Line-voltage Chip™ surface mount fuse
Environmental data
•
•
Operating Temperature Range: -65 °C to +125 °C, with proper
derating
Thermal Shock: MIL-STD-202, Method 107, Test Condition B
(-65 °C to 125 °C), 1000 cycles, fuses soldered to FR-4 glass-
epoxy circuit board
•
•
Vibration: MIL-STD-202, Method 204, Test Condition C (55 Hz
to 2000 HZ, 10 G)
Solderability: Withstands 60 seconds above 200 °C, 260 °C
maximum
•
•
Moisture Resistance: MIL-STD-202, Method 106, 10 day cycle
Solder Leach Resistance & Terminal Adhesion: EIA-576 (30
seconds submersion in 260 °C (tin-lead solder)
Product features
• Surface mount fuse, fast acting, 125Vac
• Utilize thick and thin metal film technologies for
superior fusing action and enhanced reliability.
Soldering method
•
•
Wave Immersion: 260 °C, 10 sec max.
Infrared Reflow: 260 °C, 30 sec max.
Agency information
Ordering
• UL Recognition Guide & File numbers: JDYX2 &
E19180.
•
Specify packaging and product code (i.e., TR/3216LV1-R)
• CSA Component Acceptance: 053787 C 000
& Class No: 1422 30
ELECTRICAL CHARACTERISTICS
% of Amp Rating
100%
Opening Time
4 hours minimum
5 seconds maximum
250%
SPECIFICATIONS
Interrupting
Typical Melting
Typ. Resistance
Typ. Voltage
Drop @ Rated
Current (Volts)
Current
Rating
(Amps)
250mA
375mA
750mA
1
Voltage
Rating
Vac/dc
125
125
125
125
125
125
Rating
Integral @ 10X Rated
Current (A * sec)
@ ≤ 10%
2
Part
@125Vac/dc
Rated Current
Number
(amps)
50
AC
0.00016
0.001
0.0033
0.020
0.035
0.038
DC
0.000084
0.0002
0.00379
0.0084
0.021
(Ω)
4.5
1.80
0.75
0.52
0.40
0.26
3216LV250-R
3216LV375-R
3216LV750-R
3216LV1-R
3216LV1.25-R
3216LV1.5-R
1.4
50
0.73
0.63
0.63
0.62
0.49
50
50
1.25
1.5
50
50
0.024
Notes:
1. AC interrupting rating, melting integral and total clearing integral measured at 125V, unity power factor
2. DC interrupting rating, melting integral and total clearing integral measured at 125V with a battery source
3. Voltage drop measured at 23 3°C ambient temperature with the device mounted on a suitable circuit board trace
4. It is recommended that fuses be mounted with ceramic (white) side facing up
5. Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended,
with further derating required at elevated ambient temperatures