MS-95, MS-95T
Description
Addressable Manual
Pull Station Alarm
The Gamewell-FCI MS-95 is an easily recognized manual
pull station with the distinctive bulls-eye design compatible
with the Gamewell-FCI addressable 600 Series Fire Alarm
Control Panels (FACPs). The MS-95 is approved to UL
Standard 38 for manual stations, meets architectural
requirements in all building interiors, and is readily noticed
in a fire emergency. The addressable MS-95 manual pull
station with a rugged toggle switch design offers excep-
tional resistance to accidental alarms caused by vibration
and sudden shock. The MS-95 can be used for surface and
semi-flush installations.
Operations
MS-95
The manual pull station is activated by pulling forward on
the readily identified bulls-eye alarm lever labeled “PULL”
in distinctive white letters. Once pulled, this lever locks in
the alarm position and remains there until manually reset.
Features
•
Compatible with the Gamewell-FCI 600 Series analog
addressable control panels.
To reset the alarm lever, the front cover of the pull station is
released by turning the screw on the top of the cover or
turning the key (on certain models). This unlocks the front
cover which is then lowered. Once the front cover is low-
ered, the toggle switch is reset.
•
•
•
•
•
•
•
•
•
•
Field programmable.
Durable construction.
Compact design, blends with surroundings.
Recessed pull lever prevents accidental operation.
Surface or semi-flush installation.
Double action option.
An optional breakglass rod may be used with all stations.
The self-clearing design prevents jamming of the station
and there is no danger to the operator from broken parti-
cles of glass. Space is provided within the station housing
for storage of an additional replacement glass rod.
Key reset option.
Meets ADA requirements.
Visible status LED.
Terminal block model available (MS-95T).
The MS-95 connects directly to the analog addressable
circuit via two wires. The electronic circuitry has been
designed to transmit data that can be interpreted as three
(3) output operations:
•
•
•
normal standby operation
alarm operation
trouble operation
An ISO 9000-2000 Company
SIGNALING
In its standby mode of operation, the pull station’s circuit
monitor the switch for alarm conditions. A trouble condition
S281
7150-1288:148
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
©2007 Honeywell International Inc. All rights reserved.
Specifications are for information only, are not intended for installation pwurpwoswes,.ganadmareeswubejecllt-tofcchia.cngoemwithout notice. No responsibility is assumed by Gamewell-FCI for their use.
CS-2053 Rev. A page 1 of 2