General Purpose Relays
Industrial Relays
SCHRACK
Power Relay RM 2/3/7
n
n
n
n
n
n
2/3 pole 10/16A, 2 form C (CO) or 3 form C (CO) contacts
Switching capacity up to 6000VA
DC or AC coil
Mechanical indicator
Push-to-test button
Plug-in version, PCB terminals, chassis- or DIN-rail mount
Typical applications
Elevator control, power supplies
F0163-B
Z
Approvals
VDE Cert. No. 40003144, UL E214025
Technical data of approved types on request
Contact Data (continued)
Mechanical endurance
DC coil
RM2
RM3
RM7
20x106 operations
20x106 operations
AC coil
Contact Data
Contact arrangement
RM2
2 form C
2 CO
RM3
3 form C
3 CO
RM7
3 form C
3 CO
Coil Data
Rated voltage
Max. switching voltage
Rated current
400VAC
440VAC
10A
Coil voltage range
6 to 220VDC
6 to 400VAC
2
16A
16A
40A
Operative range, IEC 61810
Coil insulation system according UL
Limiting making current, max. 20ms 40A
40A
class 130 (B)
Switching power
Contact material
6000VA
ACdO,
AgNi90/10
3800VA
AgCdO,
6000VA
AgCdO
Coil versions, DC coil
in preparation
Coil code
Rated
voltage
VDC
Coil
Rated coil
power
W
Min. recommended contact load
Frequency of operation, with/without load
Operate/release time max., DC coil
24VDC/100mA
960/6000h-1
15/10ms
STD
LED
PD3)
LED+
PD3)
resistance
bipolar
Ω 10ꢀ1)2)
Coil versions, DC coil, RM2, RM3
Bounce time max., DC coil, form A/form B
4/10ms
006
012
024
048
060
110
221
L06
L12
L24
L48
L60
M10
N21
0A6
0B2
0C4
0E8
0G0
1B0
2C1
LA6
LB2
LC4
LE8
LG0
MB0
NC1
6
12
24
48
60
110
220
32
110
475
2000
2850
100001)
400002)
1.1
1.3
1.2
1.2
1.3
1.2
1.2
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RM20 C (CO)
RM22 C (CO)
RM22 C (CO)
RM30 C (CO)
RM70 C (CO)
UL 508
16A, 400VAC, cosφ=1, 35°C
100x103
100x103
50x103
16A, 400VAC, cosφ=1, DC-coil, 70°C
16A, 400VAC, cosφ=1, AC-coil, 60°C
10A, 400VAC, cosφ=1, 35°C
Coil versions, DC coil, RM7
100x103
100x103
006
012
024
048
060
110
221
L06
L12
L24
L48
L60
M10
N21
0A6
0B2
0C4
0E8
0G0
1B0
2C1
LA6
LB2
LC4
LE8
LG0
MB0
NC1
6
12
24
48
60
110
220
24
86
345
1340
2200
7300
300002)
1.5
1.7
1.7
1.7
1.6
1.7
1.6
16A, 400VAC, cosφ=1, 35°C
RM2
RM2
RM20 A (NO)
A (NO)
A (NO)
16A, 277VAC, general purpose, 70°C
16A, 415VAC, resistive, 70°C
10A, 48VDC, 50°C
30x103
100x103
30x103
RM3
RM3
C (CO)
C (CO)
10A, 415VAC, resistive, DC-coil, 70°C
10A, 415VAC, resistive, AC-coil, 55°C
100x103
100x103
Operate voltage, DC coil
Release voltage, DC coil
1) Coil resistance 12ꢀ, 2) Coil resistance 15ꢀ
3) Protection diode PD; standard polarity: +A1 / -A2
75ꢀ of rated coil voltage
10ꢀ of rated coil voltage
RM30 A (NO)/B (NC) 10A, 277VAC, gen. purp., DC-coil, 70°C 30x103
RM30 A (NO)/B (NC) 10A, 277VAC, gen. purp., AC-coil, 55°C 30x103
RM7
RM7
A (NO)
16A, 415VAC, resistive, 50°C
100x103
30x103
All figures are given for coil without pre-energization, at ambient temperature +23°C
A (NO)/B (NC) 16A, 277VAC, general purpose, 50°C
1
04-2015, Rev. 0415
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company