Altech Corp.
Circuit Protection Devices
V-EA Circuit Breakers, DIN Rail Mount (Continued)
“G” Characteristic (Continued)
“G” One Pole
“G” Two Pole
“G” Three Pole
EACH
Rated
Current
EACH
EACH
Stock
No.
Mfr.’s
Type
Stock
No.
Mfr.’s
Type
Stock
No.
Mfr.’s
Type
1-24
25-Up
1-24
25-Up
1-24
25-Up
3.00 A
3.50 A
501-2106
501-2107
501-2110
501-2112
501-2114
501-2116
501-2096
501-2097
501-2098
501-2099
501-2100
501-2101
501-2104
501-2105
501-2108
501-2109
501-2111
501-2113
501-2115
1GU3
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
17.84
20.54
21.12
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
16.35
18.83
19.36
501-2363
501-2364
501-2367
501-2369
501-2371
501-2373
501-2353
501-2354
501-2355
501-2356
501-2357
501-2358
501-2361
501-2362
501-2365
501-2366
501-2368
501-2370
501-2372
2GU3
39.84
39.84
39.84
39.84
37.22
37.22
37.22
37.22
37.22
37.22
37.22
37.22
38.19
38.19
39.84
39.84
46.20
49.66
54.39
36.52
36.52
36.52
36.52
34.12
34.12
34.12
34.12
34.12
34.12
34.12
34.12
35.00
35.00
36.52
36.52
42.35
45.53
49.86
501-2526
501-2527
501-2530
501-2532
501-2534
501-2536
501-2516
501-2517
501-2518
501-2519
501-2520
501-2521
501-2524
501-2525
501-2528
501-2529
501-2531
501-2533
501-2535
3GU3
60.66
60.66
60.66
60.66
56.99
56.99
56.99
56.99
56.99
56.99
56.99
56.99
56.99
56.99
56.99
56.99
70.40
76.96
83.32
55.51
55.61
55.61
55.61
52.24
52.24
52.24
52.24
52.24
52.24
52.24
52.24
52.24
52.24
52.24
52.24
64.53
70.55
76.38
1GU3.5
1GU4
2GU3.5
2GU4
3GU3.5
3GU4
4.00 A
5.00 A
1GU5
2GU5
3GU5
6.00 A
1GU6
2GU6
3GU6
8.00 A
1GU8
2GU8
3GU8
10.00 A
12.00 A*
12.50 A
13.00 A
15.00 A*
16.00 A
20.00 A
25.00 A
30.00 A*
32.00 A
40.00 A
50.00 A
60.00 A*
1GU10
1GU12
1GU12.5
1GU13
1GU15
1GU16
1GU20
1GU25
1GU30
1GU32
1GU40
1GU50
1GU60
2GU10
2GU12
2GU12.5
2GU13
2GU15
2GU16
2GU20
2GU25
2GU30
2GU32
2GU40
2GU50
2GU60
3GU10
3GU12
3GU12.5
3GU13
3GU15
3GU16
3GU20
3GU25
3GU30
3GU32
3GU40
3GU50
3GU60
6
*Not European standard rating.
“Z” Characteristic
2
Thermal one hour trip zone 1.05 to 1.35 times rated current (RC); Magnetic 100 ms trip zone 2 to
3 times RC. Semiconductor protection. The “Z” characteristic is intended for protection of loads
that can withstand only very low I t energy exposure (e.g. some electronic circuits). The magnetic
trip is very fast. The thermal trip curve is the same as the “G” and meets USA, Canadian norms.
“Z” One Pole
“Z” Two Pole
“Z” Three Pole
Rated
Current
EACH
EACH
EACH
Stock
No.
Mfr.’s
Type
Stock
No.
Mfr.’s
Type
Stock
No.
Mfr.’s
Type
1-24
25-Up
1-24
25-Up
1-24
25-Up
0.30 A
0.50 A
501-2117
501-2118
501-2119
501-2120
501-2121
501-2128
501-2129
501-2132
501-2133
501-2136
501-2137
501-2138
501-2139
501-2122
501-2123
501-2124
501-2125
501-2126
501-2127
501-2130
501-2131
501-2134
501-2135
1ZU03
1ZU05
1ZU075
1ZU1
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
26.62
24.50
24.50
24.50
24.50
24.50
24.50
24.50
24.50
24.50
24.50
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
24.40
22.46
22.46
22.46
22.46
22.46
22.46
22.46
22.46
22.46
22.46
501-2397
501-2398
501-2399
501-2400
501-2401
501-2408
501-2409
501-2412
501-2413
501-2416
501-2417
501-2418
501-2419
501-2402
501-2403
501-2404
501-2405
501-2406
501-2407
501-2410
501-2411
501-2414
501-2415
2ZU03
2ZU05
2ZU075
2ZU1
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
53.52
51.41
51.41
51.41
51.41
51.41
51.41
51.41
51.41
51.41
51.41
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
49.06
47.12
47.12
47.12
47.12
47.12
47.12
47.12
47.12
47.12
47.12
501-2537
501-2538
501-2539
501-2540
501-2541
501-2548
501-2549
501-2552
501-2553
501-2556
501-2557
501-2558
501-2559
501-2542
501-2543
501-2544
501-2545
501-2546
501-2547
501-2550
501-2551
501-2554
501-2555
3ZU03
3ZU05
3ZU075
3ZU1
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
107.34
101.65
101.65
101.65
101.65
101.65
101.65
101.65
101.65
101.65
101.65
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
98.40
93.18
93.18
93.18
93.18
93.18
93.18
93.18
93.18
93.18
93.18
0.75 A
1.00 A
1.60 A
1ZU1.6
1ZU2
2ZU1.6
2ZU2
3ZU1.6
3ZU2
2.00 A
2.50 A
1ZU2.5
1ZU3
2ZU2.5
2ZU3
3ZU2.5
3ZU3
3.00 A
3.50 A
1ZU3.5
1ZU4
2ZU3.5
2ZU4
3ZU3.5
3ZU4
4.00 A
5.00 A
1ZU5
2ZU5
3ZU5
6.00 A
1ZU6
2ZU6
3ZU6
8.00 A
1ZU8
2ZU8
3ZU8
10.00 A
12.00 A*
12.50 A
13.00 A
15.00 A*
16.00 A
20.00 A
25.00 A
30.00 A*
32.00 A
1ZU10
1ZU12
1ZU12.5
1ZU13
1ZU15
1ZU16
1ZU20
1ZU25
1ZU30
1ZU32
2ZU10
2ZU12
2ZU12.5
2ZU13
2ZU15
2ZU16
2ZU20
2ZU25
2ZU30
2ZU32
3ZU10
3ZU12
3ZU12.5
3ZU13
3ZU15
3ZU16
3ZU20
3ZU25
3ZU30
3ZU32
*Not European standard rating.
Ampere Rating and Horsepower Rating
Horsepower Rating: Single Phase, One Pole V-EA
Horsepower Rating: Three Phase, Three Pole V-EA†
Horsepower @ Nominal Line Voltage, 1ø
Horsepower @ Nominal Line Voltage, 3ø Listed By Motor Design
200 V 208 V 220-240 V
B, C, D B, C, D B, C, D
V-EA
Rated
Current
V-EA
Rated
Current
110-120 V
B, C, D
440-480 V
B, C, D E
110-
220-
200 V 208 V
265 V 277 V
120 V
240 V
E
E
E
E
1
1
3
1
1.00 A
2.00 A
2.50 A
3.00 A
3.50 A
4.00 A
5.00 A
6.00 A
8.00 A
10.00 A
12.00 A
12.50 A
13.00 A
15.00 A
16.00 A
—
—
—
—
—
—
—
—
—
—
1
1.00 A
1.60 A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
/
/
/
2
2
4
/
/
/
2
2
4
1
1
1
3
—
—
/
/
/
/
/
/
/
6
6
4
4
3
2
2
/
6
6
4
3
3
2
4
/
6
4
3
3
3
2
4
—
—
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
3
1
1
/
6
6
4
4
3
2
4
/
6
6
4
3
2
2
4
/
/
/
/
/
/
/
/
/
/
/
/
2.00 A
—
—
—
/
2
2
2
4
4
/
2
2
2
4
4
1
1
1
1
1
3
1
1
1
1
1
3
1
1
1
1
1
1
3
3
1
1
3
3
/
/
/
/
/
/
/
/
/
/
/
/
2.50 A
/
/
/
/
2
2
2
4
/
2
2
2
4
/
2
2
4
4
/
2
2
4
4
/
/
/
/
/
/
/
/
1
1
1
1
3
1
1
3
1
3
3
1
3
3
3.00 A
/
/
/
/
/
/
/
/
/
11/
2
2
11/
2
2
—
3.50 A
1
/
/
/
/
/
/
/
/
6
4
3
2
2
2
2
4
4.00 A
—
—
2
2
1
1
1
1
1
1
3
1
1
5.00 A
/
2
2
4
/
2
2
4
1
1
1
1
2
2
3
3
3
3
3
5
5
5
5
1
1
2
2
3
3
3
3
3
5
1
1
2
2
3
3
3
3
3
5
1
1
3
3
1
3
1
3
6.00 A
/
/
/
/
11/
2
2
11/
2
2
3
3
1
1
1
2
2
2
2
3
3
3
5
5
5
1
1
11/
2
2
11/
2
2
8.00 A
2
5
5
11/
11/
11/
2
2
2
2
11/
11/
11/
2
2
2
2
10.00 A
12.00 A
12.50 A
13.00 A
15.00 A
16.00 A
20.00 A
25.00 A
30.00 A
32.00 A
40.00 A
50.00 A
60.00 A
1
1
2
3
3
5
5
11/
11/
11/
2
2
2
2
11/
11/
11/
2
2
2
2
3
3
3
71/
71/
71/
2
2
2
71/
71/
71/
2
2
2
2
2
2
2
3
3
3
2
3
3
3
3
1
2
2
2
3
3
3
3
10
10
20.00 A 11/
2
3
3
3
3
2
2
3
5
5
10
10
15
20
20
30
30
40
10
10
15
20
20
20
25
30
25.00 A
30.00 A
32.00 A
40.00 A
50.00 A
60.00 A
2
2
2
3
3
5
3
3
3
5
3
3
5
5
5
3
3
5
71/
71/
10
10
15
20
2
2
71/
2
2
71/
2
71/
2
3
3
5
5
5
5
5
71/
10
10
3
5
5
5
5
71/
2
71/
2
71/
2
71/
10
15
2
5
5
5
10
71/
10
10
10
10
15
20
10
10
10
15
71/
2
10
10
10
10
10
10
5
5
10
15
15
71/
10
10
2
2
71/
2
71/
2
10
10
10
*Conversions per UL508 table 45.2 and NFPA-70, National
Electrical Code® 1999 tables 430-148 and 430-151A.
†Conversions per UL508 table 45.2, 45.4 and NFPA-70, National Electrical Code® 1999 tables 430-149, 430-150 and 430-151B.
274
ꢀ
ALLIED