HIGH FREQUENCY MAGNETICS
Specialty Through Hole Shielded Transformer
TM00105
•
Operates as high frequency pulse transformer or as
high frequency analog transformer in various
telecom circuits requiring very high voltage step-up
ratio
•
•
•
Operating temperature range: -40° C to +85° C
Meets IEC 695, 2-2 flammability requirements
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning
•
•
Interwinding Electrostatic Shield provides low
capacitance and high EMI suppression
•
Reliability testing: shock, vibration, temperature cycling,
temperature - humidity - bias
Electrical equivalents: 2664F, 2779A
ELECTRICAL SPECIFICATIONS AT 25° C
DCR
Ω
max
Leakage
Inductance2
µH max
Turns Ratio
±1%
Inductance2
µH Min
Interwinding Capacitance
pF max
Minimum
Interwinding
Breakdown
Voltage
Part Number
(3-7) : (2-1)1
(2-5)
(3-8)(4-7)(2-1)3
(3-7)1
(3-8) to 64 (4-7) to 64
(3-7) : (2-1)5
Vrms
2741P2
1 CT : 25 CT
300
1.92
0.2
5
5
5
500
1. connect 4 to 8
4. with (2-1) grounded
2. measured at 100kHz, 0.02 Vac
3. connect 4 to 8 & 2 to 7
5. with 6 grounded and 4 connected to 8
SCHEMATIC
2741P2
2
5
3
8
4
CT
CT
1
7
6
1 : 25
©2000 Bel Fuse Inc. Specifications subject to change without notice. 09.00
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
T1-11