HRCII CURRENT LIMITING FUSES
600V a.c. or less, 250V d.c. 200,000 A.I.R. to CSA C22.2 No. 106 M92
Edison HRCII Fuses
- Engineered for long life reliable protection.
- Non deteriorating silver plated links.
- High grade ceramic bodies.
For full “no damage” protection under all fault conditions
(Type 2 Coordination - per IEC 947-4), and to avoid nui-
sance fuse operation, the fuse, relay and contactor charac-
teristics must be considered together to ensure that:
- the contactor is protected at all times
- Plated external metalwork.
- Interrupting rating certified to 200,000 Amps RMS sym-
metrical, to CSA C22.2 No. 106M1992.
- HRCII fuse manufacturing is certified to ISO 9002 (1987)
standard.
- the overload relay operates before the fuse (up to the
relay’s safe interrupting limit), or
- the fuse safely clears the circuit and limits high level
fault currents to prevent damage to the relay or to the
contactor.
Applications
HRCII fuses are often used to protect motor control circuits,
together with contactors and overload protection relays.
This is particularly necessary in the case of IEC style con-
tactors, which require more accurate coordination to ensure
optimum system reliability.
In this application overload protection of the installation is
provided by the thermal overload relay, and the fuses are
usually rated higher than the motor full load current to avoid
nuisance blowing under starting inrush currents.
In addition CSA certified, Edison HRCII fuses are also test-
ed and certified to IEC and British standards. IEC269:2 and
BS88:2 include tightly specified characteristics to ensure full
interchangeability with other manufacturers HRCII fuses
certified to these standards.
This arrangement allows the use of a fast-acting *fuse char-
acteristic which ensures excellent short-circuit current and
energy limiting for optimum protection.
For further information on fuse selection and coordination
contact your local Edison Fusegear representative.
*CSA defined HRCII characteristics inherently give more time delay than
HRCI fast acting fuses.
Cross Reference
AMPERE
RATING
2-30
40-60
80-100
80-100+
125-200
125-200+
250-400
250-400+
450-600
EDISON
H07C
K07C
L14C
L09C
M09C
M14C
P11C
P09C
R11C
DORMAN*
AAO
BAO
CEO
CD
DD
DEO
EF
GEC/ENGLISH
FUSETEK
2CO
2CO
2CO
2CM
2CC
2CM
2CC
2CM
2CC
GOULD
BUSSMANN
SIEMENS
3NW211
2NW212
3NW213
2NW222
3NW223
3NW214
3NW231
3NW224
3NW233
CIA
CIS
CCP
CC
FES, GIA
FES, GIS
FES, GCP
FESC, GC
FESC, GF
FES, GFP
FESC, GM
FESF, GMF
FESC, GLM
CGL
CGL
CGL
–
CGL
–
CGL
–
CGL
CF
CFP
CM
CMF
CLM
ED
FF
*HRCII fuses manufactured by Dorman Smith now available as Edison.
+HRCII-MISC.
102