MINIATURE FUSES
250V
Specifications
5x20 mm/ No. 230
Time-Current Characteristic
Packaging
Very Quick Acting (FF)
000: Bulk (1.000 pcs.)
002: Pack (100 pcs.)
Standard
None
Materials
Tube:
Ceramic
Approvals
None
End Caps: Nickel-plated brass
Operating Temperature
-25 ºC to +70 ºC (consider de-rating)
Climatic Category
-25 ºC/+70 ºC/21 days (EN 60068-1..3)
Stock Conditions
+10 ºC to +60 ºC
Dimensions (mm)
relative humidity ≤ 75 % yearly average,
without dew
Vibration Resistance
∅ 5,2
24 cycles at 15 min. each (EN 60068-2-6)
10 - 60 Hz at 0.75 mm amplitude
60 - 2000 Hz at 10 g acceleration
20
Marking
, FF, Current Rating, 250V, E
Limits for Pre-arcing Time
Rated Current
1.60 A ... 10.00 A
1.0 x IN
> 1 h
1.5 x IN
2.75 x IN
4 x IN
10 x IN
< 30 min 2 ms ... 100 ms 1 ms ... 25 ms < 3 ms
Permissible continuous operating current is ≤ 80 % at ambient temperature of 23 ºC (73.4 ºF).
Rated
Amp
Voltage
Rating
Breaking
Capacity
Voltage Drop Power Dissipation Melting Integral
Approvals
Current
Code
1.0 x IN
1.5 x IN
10 x IN
max. (A2s)
max. (mV)
max. (W)
1.60 A
2.00 A
2.50 A
1160
1200
1250
1315
1400
1500
1630
1800
2100
250 V
250 V
250 V
250 V
250 V
250 V
250 V
250 V
250 V
1000
600
0.12
0.35
0.44
0.75
1.60
2.50
5.00
10.00
20.00
500
1000 A @ 250 V AC
50 Hz
3.15 A
480
480
500
480
400
400
4.00 A
cos ϕ = 1.0
1
5.00 A
None
1
1
1
6.30 A
8.00 A
10.00 A
1
Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered.
Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand.
Order
Information
Qty.
Order-
Number
Series
230
Amp Code
Packaging
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
012006
www.littelfuse.com