Axial Lead and Cartridge Fuses
Subminiature Glass Body
U
®
® L
®
®
MIL
2AG Slo-Blo Fuse 229/230/290/291 Series
The 2AG Slo-Blo® fuses are available in cartridge form or with axial
leads. Axial leaded fuses are board washable. 2AG fuses provide the
same performance characteristics as their 3AG counterpart, while
occupying one-third the space. Sleeved fuses are available.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Opening
Time
Rating
110%
135%
4 hours, Minimum
1 hour, Maximum
3 seconds, Minimum
20 seconds, Maximum
200%
AGENCY APPROVALS: Listed by Underwriters Laboratories and
Certified by CSA through 3.5 amperes. Recognized under the
Components Program of Underwriters Laboratories from 4 through 7
amperes. 229 004 and 229 005 approved by MITI. 230 001 through 230
005 approved by METI.
AGENCY FILE NUMBERS: UL E10480, CSA LR 29862.
FUSES TO MIL SPEC: 229 and 230 Series are available to DSCC
Drawing #87108. To order, change 229 to 290 or 230 to 291.
INTERRUPTING RATINGS:
229 000 Series
230 000 Series
4.5 (.177")
0.635
(.025")
4.5
(.177")
0.25–3.5A
4–7A
0.25–1A
1.25–3.5A
10,000 amperes at 125VAC
400 amperes at 125VAC
35 amperes at 250VAC
100 amperes at 250VAC
14.48
(.57")
14.48
(.57")
38.1
(1.50") TYP.
Axial Lead Material: Solder coated copper.
OPTIONS: 230 Series available on tape and reel.
PACKAGING SPECIFICATIONS: Tape and Reel per EIA-296; T1:
52.4mm (2.062") taped spacing; For 1,500 per reel, 10mm (.40") spac-
ing, add packaging suffix, DRT1. For 2,500 per reel, 5mm (.20") spacing,
add packaging suffix, ERT1.
®
2AG Indicating Slo-Blo Type Fuse
The 2AG Indicating Slo-Blo® fuse instantly identifies itself upon
opening by showing a discoloration of its glass body. Guesswork
and time consuming circuit testing are eliminated. This unique
design offers the same quality performance characteristics as
the standard 2AG fuse design.
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature: –55°C to 125°C.
Shock: MIL-STD-202, Method 213, Test Condition I
(100 G’s peak for 6 milliseconds).
Vibration: MIL-STD-202, Method 201 (10–55 Hz, 0.06 inches
total excursion).
Salt Spray: MIL-STD-202 Method 101, Test Condition B (48 hours).
Insulation Resistance (After Opening): MIL-STD-202, Method 302,
Test Condition B.
Resistance to Soldering Heat: (Axial Leaded Fuses):
MIL-STD-202, Method 210A, Test Condition B (260°C, 3 Seconds).
Thermal Shock: MIL-STD-202, Method 107,
Test Condition B (–65°C to 125°C).
Moisture Resistance: MIL-STD-202, Method 106
(90-98% RH, 65°C).
PEAK WITHSTAND CURRENT (lp): These fuses will withstand 50
repetitions of a double exponential impulse wave having peak currents
(lp) and peak voltages as listed.
PHYSICAL SPECIFICATIONS:
Materials: Glass Body, Nickel-Plated Brass Fuse Caps.
(Insulating sleeve option available).
Soldering parameters:
Wave solder — 500°F (260°C), 3 seconds Max.
Reflow solder — Not recommended.
Solderability: (Axial Leaded Fuses): MIL-STD-202,
Method 208.
PACKAGING SPECIFICATIONS: Tape and Reel pitch per
EIA-296;T1: 52.4mm (2.062") taped spacing; For 1,500 per reel, add
packaging suffix, DRT1. For 2,500 per reel, 5mm (.20") add packaging
pitch suffix, ERT1. Insulating sleeve option available.
* When ordering the 2AG Indicating Slo-Blo Fuse, an ‘S’ is
required after the catalog number.
Example:
-1A Indicating Slo-Blo® Fuse = 230 001S
NOTE: LF logo, series number, amperage rating, voltage rating, and UL and CSA logos are
stamped on the fuse caps.
288